The Flex-It™ Stylet Is Less Effective than a Malleable Stylet for Orotracheal Intubation Using the GlideScope®
Authors:
- Timothy P. TurkstraTTTimothy P. Turkstra
- Philip M. JonesPJPhilip M. Jones
- Katherine M. OwerKOKatherine M. Ower
- Michelle L. GrosMGMichelle L. Gros
- 1 December 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 109 (6) , 1856-1859
Abstract
The GlideScope videolaryngoscope (Verathon Medical, Bothell, WA) usually provides excellent glottic visualization, but directing an endotracheal tube through the vocal cords can be challenging. The goal of the study was to compare the dedicated Flex-It stylet (FIS, Parker Medical, Highlands Ranch, CO) with a malleable stylet, as assessed by time to intubation (TTI). Eighty patients requiring orotracheal intubation for elective surgery were randomly allocated to either the FIS or a malleable stylet (control) to facilitate tracheal intubation using the GlideScope. TTI was recorded by blinded assessors; operators were blinded until after laryngoscopy. The operator assessed the ease of intubation using a 100-mm visual analog scale (0 = easy to 100 = difficult). The number of intubation attempts, number of failures, glottic grades, and use of external laryngeal manipulation were documented. The median TTI was 41 s (interquartile range [IQR] 30-51) for the Flex-It group compared with 32 s (IQR 28-42) for the control group (P = 0.03). The median visual analog scale score for ease of intubation was 20 (IQR 11-39) for the Flex-It group compared with 15 (IQR 8-28) for the control group (P = 0.13). The overall incidence of a Cormack-Lehane Grade I or II glottic view was 100%. In a group of experienced operators using the GlideScope, the FIS was less effective for orotracheal intubation than a malleable endotracheal tube stylet.Keywords
This publication has 16 references indexed in Scilit:
- The GlideScope®-specific rigid stylet and standard malleable stylet are equally effective for GlideScope® useCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2007
- Penetrating Injury of the Soft Palate During GlideScope® IntubationAnesthesia & Analgesia, 2007
- Anterior Tonsillar Pillar Perforation During Glidescope® Video LaryngoscopyAnesthesia & Analgesia, 2007
- Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope®Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2007
- Complications associated with the use of the GlideScope® videolaryngoscopeCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2007
- Tracheal intubation with the glidesSope® videolaryngoscope, using a “J” shaped endotracheal tubeCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2006
- Considerations aimed at facilitating the use of the new GlideScope® videolaryngoscopeCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- ReplyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- The GlideScope® video laryngoscopeAnaesthesia, 2005
- Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patientsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005