The Effect of C-Arm Malrotation on Iliosacral Screw Placement
Authors:
- Philip WolinskyPWPhilip Wolinsky
- Mark LeeMLMark Lee
- 1 August 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 21 (7) , 427-434
Abstract
We sought to determine whether inaccurate C-arm positioning could create images that lead to inaccurate interpretation of iliosacral screw positions. Cadaveric dissection study. The learning institute of Zimmer Inc. in Warsaw, Indiana. A laboratory investigation was performed using 3 nonpreserved cadaveric specimens. Several anatomic landmarks of the pelvis were outlined using radiographic markers and guide wires placed in several positions within the pelvis in each specimen. Using C-arm images we inserted the following: a "good" wire (GW), an out-the-front (OTF) wire, an out-the-back (OTB) wire placed into the sacral canal, an "in-out-in" (IOI) wire, and a wire in the S1 foramen (S1). The C-arm was then canted in 2-degree increments toward the head and then toward the feet starting from the optimum position. Properly positioned wires always appear to be contained within bone regardless of the amount of malrotation of the C-arm from the optimum inlet and outlet views. Improper malrotated fluoroscopic inlet and outlet views of the pelvis will distort the anatomic landmarks of the pelvis before improperly placed guide wires appear to be correctly placed. Properly placed guide wires will always appear correctly positioned regardless of the malrotation of the C-arm. "Malrotated" views, however, can be used to rule out certain incorrect screw positions.Keywords
This publication has 13 references indexed in Scilit:
- Inadvertent Intraforaminal Iliosacral Screw Placement Despite Apparent Appropriate Positioning on Intraoperative FluoroscopyJournal of Orthopaedic Trauma, 2005
- The Effect of Sacral Fracture Malreduction on the Safe Placement of Iliosacral ScrewsJournal of Orthopaedic Trauma, 2003
- Fluoroscopic Positioning of Sacroiliac Screws in 88 Patients2002
- Fluoroscopy-Based Multiplanar Image Guidance for Insertion of Sacroiliac ScrewsClinical Orthopaedics and Related Research, 2002
- Iliosacral Screw Insertion Using Computer-Assisted CT Image Guidance: a Laboratory StudyComputer Aided Surgery, 1998
- Author's Reply: Regarding Safe and Effective Placement of Ileosacral ScrewsJournal of Orthopaedic Trauma, 1996
- Projection of the S2 Pedicle Onto the Posterolateral Surface of the IliumSpine, 1996
- Radiographic Recognition of the Sacral Alar Slope for Optimal Placement of Iliosacral Screws: A Cadaveric and Clinical StudyJournal of Orthopaedic Trauma, 1996
- Radiologic Evaluation of Iliosacral Screw PlacementSpine, 1996
- Posterior Sacroiliac Fixation Using a Sacral Pedicle Targeting Device: An Anatomical StudyJournal of Orthopaedic Trauma, 1993