Preprocessing, analysis and quantification in single‐voxel magnetic resonance spectroscopy: experts' consensus recommendations
Top Cited Papers
- 21 February 2020
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (5) , e4257
Abstract
Once an MRS dataset has been acquired, several important steps must be taken to obtain the desired metabolite concentration measures. First, the data must be preprocessed to prepare them for analysis. Next, the intensity of the metabolite signal(s) of interest must be estimated. Finally, the measured metabolite signal intensities must be converted into scaled concentration units employing a quantitative reference signal to allow meaningful interpretation. In this paper, we review these three main steps in the post‐acquisition workflow of a single‐voxel MRS experiment (preprocessing, analysis and quantification) and provide recommendations for best practices at each step.Keywords
Funding Information
- Canadian Institutes of Health Research (PJT‐148751, PJT‐165869)
- Santé (FRQ: 0000035275)
- Natural Sciences and Engineering Research Council of Canada (RGPIN‐2017‐03875, RGPIN‐2014‐06072)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (320030‐175984)
- National Institute of Biomedical Imaging and Bioengineering (P41 EB015894)
- National Institute of Neurological Disorders and Stroke (R01 NS080816)
This publication has 112 references indexed in Scilit:
- 2-hydroxyglutarate detection by magnetic resonance spectroscopy in IDH-mutated patients with gliomasNature Medicine, 2012
- Spectroscopic imaging with prospective motion correction and retrospective phase correctionMagnetic Resonance in Medicine, 2011
- Real‐time motion and B0 correction for localized adiabatic selective refocusing (LASER) MRSI using echo planar imaging volumetric navigatorsNMR in Biomedicine, 2011
- Real‐time motion and B0 corrected single voxel spectroscopy using volumetric navigatorsMagnetic Resonance in Medicine, 2011
- Prospective motion correction for magnetic resonance spectroscopy using single camera retro‐grate reflector optical trackingJournal of Magnetic Resonance Imaging, 2011
- Prospective motion correction for single‐voxel 1H MR spectroscopyMagnetic Resonance in Medicine, 2010
- Age dependence of regional proton metabolites T2 relaxation times in the human brain at 3 TMagnetic Resonance in Medicine, 2008
- A practical guide to robust detection of GABA in human brain by J-difference spectroscopy at 3 T using a standard volume coilMagnetic Resonance Imaging, 2007
- Monitoring and correcting spatio-temporal variations of the MR scanner’s static magnetic fieldMagnetic Resonance Materials in Physics, Biology and Medicine, 2006
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993