Detorque Evaluation of Dental Abutment Screws after Immersion in a Fluoridated Artificial Saliva Solution
- 25 October 2012
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 22 (4) , 275-281
Abstract
Purpose Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Materials and Methods Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conexão®, (E) Emfils®, (I) INP®, (S) SIN®, and (T) Titanium Fix®. The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20 Ncm using a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronic microscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Results Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. Conclusion An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions.Keywords
This publication has 40 references indexed in Scilit:
- Biofilms Inducing Ultra-low Friction on TitaniumJournal of Dental Research, 2010
- Present status of titanium removable dentures – a review of the literature*Journal of Oral Rehabilitation, 2008
- Influence of fluoride concentration and pH on corrosion behavior of Ti‐6Al‐4V and Ti‐23Ta alloys in artificial salivaMaterials and Corrosion, 2007
- Electrochemical properties of suprastructures galvanically coupled to a titanium implantJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- Galvanic corrosion behavior of implant suprastructure dental alloysDental Materials, 2003
- Bacterial leakage into and from prefabricated screw‐retained implant‐borne crowns in vitroJournal of Oral Rehabilitation, 1998
- Comparison of screw retention of nine abutment systemsImplant Dentistry, 1997
- Bacterial colonization on internal surfaces of Brånemark system® implant componentsClinical Oral Implants Research, 1996
- Effect of corrosion on the strength of soldered titanium and Ti 6Al 4V alloyDental Materials, 1996
- Study of corrosion between a titanium implant and dental alloysJournal of Dentistry, 1994