A Comparative Study of Single-pulse and Double-pulse Laser-Induced Breakdown Spectroscopy with Uranium-containing Samples
- 25 January 2016
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (3) , 467-473
Abstract
Laser-induced breakdown spectroscopy (LIBS) holds potential advantages in special nuclear material (SNM) sensing and nuclear forensics, which require rapid analysis, minimal sample preparation, and stand-off distance capability. SNM, such as U, however, result in crowded emission spectra with LIBS, and characteristic emission lines are challenging to discern. It is well-known that double-pulse LIBS (DPLIBS) improves the signal intensity for analytes over conventional single-pulse LIBS (SPLIBS). This study investigates the U signal in a glass matrix using DPLIBS and compares it to signal obtained using SPLIBS. Double-pulse LIBS involves sequential firing of a 1.06 µm Nd:YAG pre-pulse and 10.6 µm TEA CO 2 heating pulse in a near collinear geometry. Optimization of experimental parameters including inter-pulse delay and energy follows identification of characteristic lines for the bulk analyte Ca and the minor constituent analyte U for both DPLIBS and SPLIBS. Spatial and temporal coupling of the two pulses in the proposed DPLIBS technique yields improvements in analytical merits with a negligible increase in damage to the sample compared to SPLIBS. Subsequently, the study discusses optimum plasma emission conditions of U lines and relative figures of merit in both SPLIBS and DPLIBS. Investigation into plasma characteristics also addresses plausible mechanisms related to the observed U analyte signal variation between SPLIBS and DPLIBS.Keywords
This publication has 24 references indexed in Scilit:
- Determination of uranium concentration in an ore sample using laser-induced breakdown spectroscopySpectrochimica Acta Part B: Atomic Spectroscopy, 2012
- Detection of Uranium Using Laser-Induced Breakdown SpectroscopyApplied Spectroscopy, 2009
- Thermodynamic and spectroscopic properties of Nd:YAG–CO2 Double-Pulse Laser-Induced Iron PlasmasSpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Laser-induced breakdown spectroscopy for determination of uranium in thorium–uranium mixed oxide fuel materialsTalanta, 2009
- Double pulse laser ablation and plasma: Laser induced breakdown spectroscopy signal enhancementSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS for isotope analysis of long-lived radionuclidesInternational Journal of Mass Spectrometry, 2005
- Three-dimensional analysis of laser induced plasmas in single and double pulse configurationSpectrochimica Acta Part B: Atomic Spectroscopy, 2004
- Reference lines in the optogalvanic spectra of uranium and thorium over the wavelength range 694–755 nmJournal of the Optical Society of America B, 2002
- A comparison of single and double pulse laser-induced breakdown spectroscopy of aluminum samplesSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Uranium(VI) speciation by spectroscopyJournal of Radioanalytical and Nuclear Chemistry, 1997