Accuracy of a chairside, fused deposition modeling three‐dimensional‐printed, single tooth surgical guide for implant placement: A randomized controlled clinical trial
Authors:
- 27 July 2022
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 33 (10) , 1000-1009
Abstract
Purpose: To compare the accuracy of chairside, fused deposition modeling (FDM) three‐dimensional (3D)‐printed surgical guides with that of stereolithographic guides for implant placement in single edentulous sites within a clinical setting.Materials and Methods: A total of 28 participants with 30 single posterior edentulous sites were included. The sites were randomized into a FDM 3D‐printed surgical guide group (test) or stereolithographic guide group (control) of equal size (n = 15). In both groups, digital implant planning was performed using data from cone beam‐computed tomography and intraoral scans. The test group's surgical guides were fabricated using a chairside, FDM 3D‐printer; those in the control group were fabricated using a light‐curing 3D‐printer. Postoperative intraoral scans were used to obtain the 3D position of the implants. Compared to preoperative design, the angular, 3D, mesiodistal, buccolingual and apicocoronal deviations at the implant shoulder and apex were recorded.Results: The workflow for the design and chairside fabrication of implant guides was established. The mean angular deviations of the test and control group were (4.23 ± 2.38) ° and (4.13 ± 2.42) ° (p > .05), respectively. The respective 3D deviations at the implant shoulder were (0.70 ± 0.44) mm and (0.55 ± 0.27) mm (p > .05); those at the implant apex were (1.25 ± 0.61) mm and (1.11 ± 0.54) mm (p > .05). The mesiodistal, buccolingual, and apicocoronal deviations at the implant shoulder and apex did not significantly differ between the groups (p > .05).Conclusions: Implants for single posterior edentulous spaces were placed as accurately with the test guide as with the control. Further research under more complex situations involving multiple missing teeth is needed.Keywords
This publication has 42 references indexed in Scilit:
- Technical Accuracy of Printed Surgical Templates for Guided Implant Surgery with the coDiagnostiXTM SoftwareClinical Implant Dentistry and Related Research, 2013
- The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical StudyClinical Implant Dentistry and Related Research, 2013
- Implant Positioning Errors in Freehand and Computer-Aided Placement Methods: A Single-Blind Clinical Comparative StudyThe International Journal of Oral and Maxillofacial Implants, 2013
- Accuracy of computer‐aided implant placementClinical Oral Implants Research, 2012
- Clinical advantages of computer‐guided implant placement: a systematic reviewClinical Oral Implants Research, 2012
- Accuracy and Complications of Computer‐Designed Selective Laser Sintering Surgical Guides for Flapless Dental Implant Placement and Immediate Definitive Prosthesis InstallationJournal of Periodontology, 2012
- An overview of the recent developments in polylactide (PLA) researchBioresource Technology, 2010
- Geometric accuracy of digital volume tomography and conventional computed tomographyBritish Journal of Oral and Maxillofacial Surgery, 2008
- Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applicationsRadiation Protection Dosimetry, 2008
- Ridge alterations following implant placement in fresh extraction sockets: an experimental study in the dogJournal of Clinical Periodontology, 2005