Out-of-Step Protection Using State-Plane Trajectories Analysis
Authors:
- 26 February 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 28 (2) , 1083-1093
Abstract
This paper proposes a novel out-of-step protection technique using the state-plane representation of the generator speed and power angle. The critical clearing angle is computed using the principle that the total energy of the system at the instant the fault is cleared should be equal to the maximum potential energy of the system. The critical clearing time corresponding to the value of critical clearing angle is obtained directly using the time calibration of the relative speed versus power-angle solution curve. The simultaneous calculation of the critical clearing angle and the time make the proposed approach much faster than the two-blinder scheme. The proposed state-plane prediction scheme is used to detect the first swing out-of-step condition in a two-area test system using system-wide information. The two generators are represented with a single-machine infinite bus equivalent system, and the state-plane algorithm is applied to the reduced equivalent. Electromagnetic transient simulations are carried out using PSCAD/EMTDCTM to test the proposed algorithm in the two-area test systems. The simulation studies show that the proposed method is computationally efficient and accurate. The technique also does not require any offline studies.Keywords
This publication has 14 references indexed in Scilit:
- A predictive out of step protection scheme based on PMU enabled dynamic state estimation2011
- Application of Equal Area Criterion Conditions in the Time Domain for Out-of-Step ProtectionIEEE Transactions on Power Delivery, 2010
- Rotor Angle Instability Prediction Using Post-Disturbance Voltage TrajectoriesIEEE Transactions on Power Systems, 2009
- Out-of-step detection algorithm using frequency deviation of voltageIET Generation, Transmission & Distribution, 2007
- Transient Stability of Power Systems2000
- Adaptive protection strategies for detecting power system out-of-step conditions using neural networksIEE Proceedings - Generation, Transmission and Distribution, 1998
- A new method for power system transient instability detectionIEEE Transactions on Power Delivery, 1997
- An adaptive out-of-step relay [for power system protection]IEEE Transactions on Power Delivery, 1997
- An efficient methodology for coherency-based dynamic equivalentsIEE Proceedings C Generation, Transmission and Distribution, 1992
- A New Out-of-Step Relay with Rate of Change of Apparent Resistance AugmentationIEEE Transactions on Power Apparatus and Systems, 1983