Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: Estimation of optimal contrast material dose
Authors:
- 1 March 2013
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 54 (2) , 149-155
Abstract
Background: Body mass index (BMI) has a positive linear influence on arterial attenuation at coronary CT angiography involving injection protocol with dose linearly tailored to body weight (BW). Excessive contrast material may inadvertently be given in heavier patients when the dose is determined by BW only. Purpose: To investigate the effect of injection protocol with dose of contrast material (CM) tailored to BW and BMI on coronary arterial attenuation, contrast-to-noise ratio, and image noise at dual-source CT coronary angiography (DSCT-CA). Material and Methods: A total of 233 consecutive patients (mean age, 60.2 years) undergoing DSCT-CA were included. Image acquisition protocol was standardized (120 kV, 380 mAs, and retrospective electrocardiograph-triggered DSCT-CA). CM dosage calculation was randomly categorized into groups: a BW group and a BW-BMI group. CM flow rate in both groups was calculated as dosage divided by scan time plus 8 s. Correlations between BW, BMI, and attenuations of ascending aorta (AA) above coronary ostia, left main coronary artery (LM), proximal right coronary artery (RCA), left anterior descending (LAD), and left circumflex artery (LCX), contrast to noise ratio of LM (LMCNR) and RCA (RCACNR), and image noise were evaluated with simple linear regression for two groups individually. Results: In BW group, attenuations of AA and coronary arteries showed positive linear correlations to BW and BMI. In contrast, no relationships were found in BW-BMI group. LMCNR and RCACNR were inversely determined by BW and BMI in both groups. Image noise increased with BW and BMI increasing in two groups. Conclusion: BMI has a positive linear influence on arterial attenuation with fixed iodine per BW. The injection protocol with CM dose tailored to BW and BMI is reasonable during DSCT-CA.Keywords
This publication has 33 references indexed in Scilit:
- Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiographyThe International Journal of Cardiovascular Imaging, 2011
- Comparison of dual-source ct coronary angiography and conventional coronary angiography for detecting coronary artery diseaseThe International Journal of Cardiovascular Imaging, 2010
- 64-MDCT Coronary Angiography: Phantom Study of Effects of Vascular Attenuation on Detection of Coronary StenosisAmerican Journal of Roentgenology, 2008
- Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and ObesityAmerican Journal of Roentgenology, 2008
- Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate controlEuropean Radiology, 2006
- Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectorisEuropean Radiology, 2005
- High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary AngiographyCirculation, 2005
- Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed TomographyJACC, 2005
- Accuracy of MSCT coronary angiography with 64-slice technology: first experienceEuropean Heart Journal, 2005
- Noninvasive Coronary Angiography with 16–Detector Row CT: Effect of Heart RateRadiology, 2005