Calibration of Robotic Manipulator Systems for Cone-Beam Tomography Imaging
- 4 June 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (7) , 1384-1393
Abstract
Image reconstruction of tomographic data relies on the precise knowledge of the geometric properties of the scan system. Common tomography systems such as rotational tomography, C-arm systems, helical scanners or tomosynthesis scanners generally use motions described by few rotational or linear motion axis. We are interested in applications in nondestructive testing, where objects might have large aspect ratios and complex shapes. For these problems, more complex scan trajectories are required which can be achieved with robotic manipulator systems that have several linear or rotational degrees of freedom. For the geometric calibration of our system, instead of using an approach that scans a calibrated phantom with markers at known relative position, we propose an approach that uses one (or several) markers with unknown relative positions. The fiducial marker is then moved by a known amount along one degree of freedom, thus tracing out a ”virtual” phantom. Using the assumed spacial locations of the markers together with the locations of the markers on the imaging plane, we use a nonlinear optimisation method to estimate the orientation of the linear and rotational manipulator axis, the detector and source location and the detector orientation.Keywords
Funding Information
- Innovate U.K., the U.K.’s Innovation Agency, and the Aerospace Technology Institute (ProjecCAN) (101804)
- EPSRC (EP/R002495/1)
This publication has 21 references indexed in Scilit:
- Focal spot calibration in a digital breast tomosynthesis systemJournal of the Korean Physical Society, 2012
- Analysis of image sharpness reproducibility on a novel engineered micro-CT scanner with variable geometry and embedded recalibration softwarePhysica Medica, 2012
- Determination of System Geometrical Parameters and Consistency between Scans for Contrast-Enhanced Digital Breast TomosynthesisLecture Notes in Computer Science, 2012
- Centers and centroids of the cone-beam projection of a ballPhysics in Medicine & Biology, 2011
- Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systemsMedical Physics, 2010
- Direct determination of geometric alignment parameters for cone-beam scannersPhysics in Medicine & Biology, 2009
- Simultaneous misalignment correction for approximate circular cone-beam computed tomographyPhysics in Medicine & Biology, 2008
- An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantomsPhysics in Medicine & Biology, 2008
- Calibration of high-resolution X-ray tomography with atomic force microscopyJournal of Research of the National Institute of Standards and Technology, 2000
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984