Quantitative Analysis of Glycated Proteins
- 13 January 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 13 (2) , 336-347
Abstract
The proposed protocol presents a comprehensive approach for large-scale qualitative and quantitative analysis of glycated proteins (GP) in complex biological samples including biological fluids and cell lysates such as plasma and red blood cells. The method, named glycation isotopic labeling (GIL), is based on the differential labeling of proteins with isotopic [13C6]-glucose, which supports quantitation of the resulting glycated peptides after enzymatic digestion with endoproteinase Glu-C. The key principle of the GIL approach is the detection of doublet signals for each glycated peptide in MS precursor scanning (glycated peptide with in vivo [12C6]- and in vitro [13C6]-glucose). The mass shift of the doublet signals is +6, +3 or +2 Da depending on the peptide charge state and the number of glycation sites. The intensity ratio between doublet signals generates quantitative information of glycated proteins that can be related to the glycemic state of the studied samples. Tandem mass spectrometry with high-energy collisional dissociation (HCD–MS2) and data-dependent methods with collision-induced dissociation (CID–MS3 neutral loss scan) are used for qualitative analysis.Keywords
This publication has 30 references indexed in Scilit:
- Evaluation of HCD- and CID-type Fragmentation Within Their Respective Detection Platforms For Murine PhosphoproteomicsMolecular & Cellular Proteomics, 2011
- Human Hemolysate Glycated ProteomeAnalytical Chemistry, 2011
- Proteomics on an Orbitrap Benchtop Mass Spectrometer Using All-ion FragmentationMolecular & Cellular Proteomics, 2010
- Glycation Isotopic Labeling with 13C-Reducing Sugars for Quantitative Analysis of Glycated Proteins in Human PlasmaMolecular & Cellular Proteomics, 2010
- Precision proteomics: The case for high resolution and high mass accuracyProceedings of the National Academy of Sciences, 2008
- Strategies for proteomic analysis of non‐enzymatically glycated proteinsMass Spectrometry Reviews, 2008
- Analysis of non‐enzymatically glycated peptides: neutral‐loss‐triggered MS 3 versus multi‐stage activation tandem mass spectrometryRapid Communications in Mass Spectrometry, 2008
- Proteomic Profiling of Nonenzymatically Glycated Proteins in Human Plasma and Erythrocyte MembranesJournal of Proteome Research, 2008
- Fragmentation behavior of glycated peptides derived from D‐glucose, D‐fructose and D‐ribose in tandem mass spectrometryJournal of Mass Spectrometry, 2006
- Tracing glycoprotein structures: electrospray ionization tandem mass spectrometric analysis of sugar–peptide adductsJournal of Mass Spectrometry, 2002