Prospective evaluation of a new plate fixator for valgus-producing medial open-wedge high tibial osteotomy
- 11 September 2014
- journal article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (12) , 3707-3716
Abstract
The purpose of this study was to prospectively evaluate the clinical, radiographic, and sports-related outcome at 24 months after valgus-producing medial open-wedge high tibial osteotomy (owHTO) using a 2nd generation peek-carbon composite plate. Between 2010 and 2011, the 2nd generation PEEKPower HTO-Plate® was used for medial owHTO in 28 consecutive patients (19 men, 9 women; mean age ± SD: 45 ± 11 years; mean varus deviation ± SD: 4° ± 2°). All of the patients had an osteotomy gap height of ≤12 mm without bone grafting. Visual analog scale (VAS) for pain, WOMAC score, and Lysholm score were evaluated preoperatively and at 12 and 24 months postoperatively. Sports-related outcomes included the Tegner scale, and a self-designed questionnaire preoperatively and 24 months postoperatively. Fixation stability of the implant was evaluated radiographically in two planes by comparing the medial proximal tibial angle (MPTA) and tibial slope 2 days after medial owHTO (baseline measurements) and after implant removal (follow-up measurements). Complications were recorded during the whole study period. Compared to preoperative conditions, VAS, WOMAC, and Lysholm scores improved significantly (p < 0.05) at the 12- and 24-month follow-up. No significant differences were found between the 12- and 24-month follow-up. After 24 months, the sports frequency increased significantly (p < 0.05). No significant differences between baseline and follow-up measurements for the MPTA and tibial slope were observed. Total complication rate was 4 %, with one patient developing non-union. In the clinical practice, the 2nd generation PEEKPower HTO-Plate® is a safe and efficient implant for medial owHTO without bone grafting in patients with an osteotomy gap of ≤12 mm. III.Keywords
This publication has 77 references indexed in Scilit:
- Treatment of Schatzker Type V and VI Tibial Plateau Fractures Using a Midline Longitudinal Incision and Dual PlatingKnee Surgery & Related Research, 2013
- Carbon fiber reinforced PEEK Optima—A composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implantsJournal of the Mechanical Behavior of Biomedical Materials, 2013
- Medial proximal tibial angle after medial opening wedge HTO: A retrospective diagnostic test studyIndian Journal of Orthopaedics, 2012
- Control of Posterior Tibial Slope and Patellar Height in Open-Wedge Valgus High Tibial OsteotomyThe American Journal of Sports Medicine, 2011
- Is There a Role for High Tibial Osteotomies in the Athlete?Sports Health: A Multidisciplinary Approach, 2010
- Early full weight bearing is safe in open-wedge high tibial osteotomyActa Orthopaedica, 2010
- Evolution of open-wedge high-tibial osteotomy: experience with a special angular stable device for internal fixation without interposition materialInternational Orthopaedics, 2009
- Results of high tibial osteotomy: review of the literatureInternational Orthopaedics, 2009
- Stability of medial opening wedge high tibial osteotomy: a failure analysisInternational Orthopaedics, 2009
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007