Friction in modern total hip arthroplasty bearings: Effect of material, design, and test methodology
Authors:
Open Access
- 30 December 2015
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 230 (1) , 50-57
Abstract
The purpose of this study was to characterize the effect of a group of variables on frictional torque generated by acetabular components as well as to understand the influence of test model. Three separate test models, which had been previously used in the literature, were used to understand the effect of polyethylene material, bearing design, head size, and material combinations. Each test model differed by the way it simulated rotation of the head, the type of frictional torque value it reported (static vs. dynamic), and the type of motion simulated (oscillating motion vs. continuous motion). It was determined that not only test model may impact product ranking of fictional torque generated but also static frictional torque may be significantly larger than a dynamic frictional torque. In addition to test model differences, it was discovered that the frictional torque values for conventional and highly cross-linked polyethylenes were not statistically significantly different in the more physiologically relevant test models. With respect to bearing design, the frictional torque values for mobile bearing designs were similar to the 28-mm diameter inner bearing rather than the large diameter outer liner. Testing with a more physiologically relevant rotation showed that frictional torque increased with bearing diameter for the metal on polyethylene and ceramic on polyethylene bearings but remained constant for ceramic on ceramic bearings. Finally, ceramic on ceramic bearings produced smaller frictional torque values when compared to metal on polyethylene and ceramic on polyethylene groups.Keywords
This publication has 19 references indexed in Scilit:
- Large diameter femoral headsThe Bone & Joint Journal, 2014
- Retrieval analysis of alumina ceramic-on-ceramic bearing couplesActa Orthopaedica, 2014
- Severe Metal-induced Osteolysis Many Years After Unipolar Hip EndoprosthesisClinical Orthopaedics and Related Research, 2013
- Inflammatory Pseudotumor Complicating Metal-On-Highly Cross-Linked Polyethylene Total Hip ArthroplastyThe Journal of Arthroplasty, 2012
- Atypical Pseudotumour after Metal-On-Polyethylene Total Hip Arthroplasty Causing Deep Venous ThrombosisHIP International, 2011
- The Effects of Acetabular Shell Deformation and Liner Thickness on Frictional Torque in Ultrahigh-Molecular-Weight Polyethylene Acetabular BearingsThe Journal of Arthroplasty, 2010
- Friction moments of large metal-on-metal hip joint bearings and other modern designsMedical Engineering & Physics, 2008
- In vitro comparison of frictional torque and torsional resistance of aged conventional gamma-in-nitrogen sterilized polyethylene versus aged highly crosslinked polyethylene articulating against head sizes larger than 32 mmActa Orthopaedica, 2006
- Evolution of Alumina-on-Alumina ImplantsClinical Orthopaedics and Related Research, 2000
- The effects of material combination and lubricant on the friction of total hip prosthesesWear, 2000