Abstract
Objective: To comparatively assess the failure rate of adhesive precoated (APC) self-ligating metal brackets bonded with two different enamel surface preparation techniques: self-etching primer (SEP) and conventional two-step etch and primer method (CM). Materials and Methods: Fifty-seven patients with complete permanent dentition were included in this study. A total of 1140 APC self-ligating brackets (3M Unitek, Monrovia, Calif) were bonded using a split-mouth design. For each patient, SEP (Transbond Plus SEP, 3M Unitek) and CM (37% phosphoric acid) were used in alternate quadrants. All brackets were bonded by the same investigator after pumicing and rinsing of all of the teeth. The number, site, and date of first-time bracket failures were monitored throughout orthodontic treatment (mean, 22 months). The survival rates of the brackets were estimated by Kaplan-Meier and log-rank tests ( P < .05). The adhesive remnant index was used to determine the bond failure interface. Results: The bond failure rates were 2.97% and 2.18% for the CM and SEP, respectively. No statistically significant difference in failure rates was found between the groups. The bond failure sites were predominantly at the enamel-adhesive interface in both groups. Conclusion: This long-term in vivo study showed that the combined use of SEP and the APC bracket system can be used effectively for bonding brackets after pumicing the enamel surfaces in clinical orthodontics.Keywords
This publication has 31 references indexed in Scilit:
- Bond failure rates with a self-etching primer: A randomized controlled trialAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- In-vivo prospective comparison of bond failure rates of 2 self-etching primer/adhesive systemsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- A randomized clinical trial comparing ‘one-step’ and ‘two-step’ orthodontic bonding systemsJournal of Orthodontics, 2006
- A randomised clinical trial to investigate bond failure rates using a self-etching primerEuropean Journal of Orthodontics, 2006
- Six and 12 months' evaluation of a self-etching primer versus two-stage etch and prime for orthodontic bonding: a randomized clinical trialEuropean Journal of Orthodontics, 2004
- An evaluation and comparison of orthodontic bracket bond strengths achieved with self-etching primerAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- An in vivo investigation into bond failure rates with a new self-etching primer systemAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic bracketsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2001
- Comparisons of shear bond strength of precoated and uncoated bracketsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1997