The corneal thickness and intraocular pressure story: where are we now?
Authors:
- 4 October 2002
- journal article
- review article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 30 (5) , 334-337
Abstract
A review of the current literature was conducted regarding the effect of corneal thickness on the diagnosis of glaucoma, and the influence of excimer laser refractive surgery on intraocular pressure (IOP) measurement with Goldmann applanation tonometry. In general, normals and primary open angle glaucoma patients have a similar distribution of corneal thickness; however, there is a wide variation, ranging from 427 to 716 micro m. Normal tension glaucoma patients have a tendency towards thinner corneas than normals; however, there is an overlap of thickness measurements of more than two-thirds in 95% of patients. There is a trend for ocular hypertensives to have thicker corneas than normals, but again there is an overlap of about one-third in 95% of patients. The general trend after excimer laser refractive surgery is for a decrease in IOP, with a mean fall in IOP measured of 0.63 mmHg per dioptre correction. There is, however, a large scatter of values with some patients having the same or lower IOP post-laser, but with other patients measuring higher pressures. Corneal thickness can influence IOP measurement by Goldmann applanation tonometry; however, the magnitude of the effect is subject to much individual variation.Keywords
This publication has 30 references indexed in Scilit:
- Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertensionBritish Journal of Ophthalmology, 2001
- Intraocular Pressure and Photorefractive KeratectomyCornea, 2001
- Central Corneal Thickness of Normal Tension Glaucoma Patients in JapanJapanese Journal of Ophthalmology, 2000
- Central corneal thickness determined with optical coherence tomography in various types of glaucomaBritish Journal of Ophthalmology, 2000
- Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic11The authors have no proprietary interest in the development or marketing of any pachymeter.Ophthalmology, 1999
- The relationship between glaucoma and myopiaOphthalmology, 1999
- Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy11The authors have no proprietary interest in these or any other tonometers.Ophthalmology, 1998
- Corneal thickness and curvature in normal-tension glaucomaAmerican Journal of Ophthalmology, 1998
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975
- Über ApplanationstonometrieOphthalmologica, 1957