Surgical Outcomes of Combined 2nd-Generation Trabecular Microbypass (iStent Inject) and Cataract Surgery for the Treatment of Primary Open-Angle Glaucoma in the Saudi Population
Authors:
Open Access
- 5 August 2021
- journal article
- research article
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 10 (4) , 923-933
Abstract
Introduction To investigate the 24-month efficacy and safety of iStent inject trabecular microbypass system implantation combined with phacoemulsification in subjects with primary open-angle glaucoma (POAG) and concomitant cataract. Methods This prospective, uncontrolled, interventional case series included 36 eyes (29 subjects) with POAG of mild to moderate severity and coexisting cataract that underwent combined phacoemulsification and implantation of a second-generation trabecular microbypass stent (iStent inject®). Main outcome measures involved mean intraocular pressure (IOP), number of antiglaucoma medications, and proportional analysis of eyes with IOP ≤ 18 mmHg or ≤ 15 mmHg, or with 0 or ≥ 2 glaucoma medications. Secondary outcome measures involved the cup-to-disc ratio, corrected distance visual acuity (CDVA), and adverse issues. Results In 36 eyes, the mean IOP at baseline was 18.28 ± 2.87 mmHg, which decreased to 14.24 ± 1.36 (22.1%) and 14.46 ± 1.56 mmHg (20.9%) at 18 and 24 months, respectively (p < 0.001). At the last follow-up, 100% of eyes had an IOP ≤ 18 mmHg (vs. 50% preoperatively), and 75.7% of eyes had an IOP ≤ 15 mmHg (vs. 16.7% preoperatively); 58.3% of eyes achieved ≥ 20% IOP reduction from preoperative status. At baseline, eyes were treated with a mean of 2.35 ± 1.18 medications, which was reduced to 0.80 ± 1.04 (66% reduction) and 0.69 ± 0.95 medications (70.6% reduction) at 18 and 24 months, respectively (p < 0.001). At the last follow-up, 54.1% of eyes were medication-free (vs. 0% preoperatively) and 24.3% of eyes were treated with ≥ 2 medications (vs. 64.9% preoperatively). This combined procedure demonstrated an excellent safety profile with no reported intraoperative complications or adverse events; CDVA was maintained throughout the entire follow-up period. Conclusions This real-world series demonstrated that iStent inject device implantation at the time of phacoemulsification is a safe and effective method to decrease IOP and the necessity for antiglaucoma medications in patients with mild-to-moderate POAG and cataract; no associated vision-threatening complications were noted.Keywords
This publication has 32 references indexed in Scilit:
- Causes of vision loss worldwide, 1990–2010: a systematic analysisThe Lancet Global Health, 2013
- Second-generation Trabecular Meshwork Bypass Stent (iStent inject) Increases Outflow Facility in Cultured Human Anterior SegmentsAmerican Journal of Ophthalmology, 2012
- The Relationship between Glaucoma Medication Adherence, Eye Drop Technique, and Visual Field Defect SeverityOphthalmology, 2011
- Long-Term Outcomes of Selective Laser Trabeculoplasty (SLT) TreatmentThe Open Ophthalmology Journal, 2011
- Selective Laser TrabeculoplastyJournal of Glaucoma, 2008
- Fluctuation of Intraocular Pressure as a Predictor of Visual Field ProgressionArchives of Ophthalmology (1950), 2008
- The number of people with glaucoma worldwide in 2010 and 2020British Journal of Ophthalmology, 2006
- Trabecular bypass stents decrease intraocular pressure in cultured human anterior segmentsAmerican Journal of Ophthalmology, 2004
- Factors for Glaucoma Progression and the Effect of TreatmentArchives of Ophthalmology (1950), 2003
- The advanced glaucoma intervention study (AGIS): 7. the relationship between control of intraocular pressure and visual field deteriorationAmerican Journal of Ophthalmology, 2000