Abstract
Cardiovascular stents are commonly made from 316L stainless steel and are deployed within stenosed arterial lesions using balloon expansion. Deployment involves inflating the balloon and plastically deforming the stent until the required diameter is obtained. This plastic deformation induces static stresses in the stent, which will remain for the lifetime of the device. In order to determine these stresses, finite element models of the unit cells of geometrically different, commercially available balloon expandable stents have been created, and deployment and elastic recoil have been simulated. In this work the residual stresses associated with deployment and recoil are compared for the various stent geometries, with a view to establishing appropriate initial stress states for fatigue loading for the stents. The maximum, minimum, and mean stresses induced in the stent due to systolic/diastolic pressure are evaluated, as are performance measures such as radial and longitudinal recoil.Keywords
This publication has 13 references indexed in Scilit:
- Finite element analysis of the implantation of a balloon-expandable stent in a stenosed arteryInternational Journal of Cardiology, 2005
- Cardiovascular stent design and vessel stresses: a finite element analysisJournal of Biomechanics, 2005
- A predictive study of the mechanical behaviour of coronary stents by computer modellingMedical Engineering & Physics, 2004
- Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modellingComputational Materials Science, 2004
- Mechanical properties of coronary stents determined by using finite element analysisJournal of Biomechanics, 2001
- Mechanical behaviour modelling of balloon-expandable stentsJournal of Biomechanics, 2000
- Three-dimensional intravascular ultrasonic volumetric quantification of stent recoil and neointimal formation of two new generation tubular stentsThe American Journal of Cardiology, 2000
- Simulation of in vivo loading conditions of nitinol vascular stent structuresComputers & Structures, 1997
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994