Absorption-Mode: The Next Generation of Fourier Transform Mass Spectra
- 6 March 2012
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (6) , 2923-2929
Abstract
The Fourier transform spectrum can be presented in the absorption-mode (commonly used in FT-NMR), magnitude-mode (FT-ICR), and power-mode (engineering applications). As is routinely used in FT-NMR, it is well-known that the absorption-mode display gives a much narrower peak shape which greatly improves the spectrum; recently, the successful solution of the phase equation allowed broadband phase correction which makes it possible to apply the absorption-mode routinely in FT-ICR. With the empirical evidence provided herein, it has been confirmed that in addition to the improvement on resolving power, compared to the conventional magnitude-mode, the new absorption-mode improves the signal-to-noise ratio (S/N) of a spectrum by 1.4-fold and can improve the mass accuracy up to 2-fold with no extra cost in instrumentation. Therefore, it is worthwhile to apply and promote absorption-mode in routine FT-ICR experiments.Keywords
This publication has 46 references indexed in Scilit:
- A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometryReview of Scientific Instruments, 2011
- Variation of the Fourier Transform Mass Spectra Phase Function with Experimental ParametersAnalytical Chemistry, 2011
- Mass Spectrometry Evidence for Cisplatin As a Protein Cross-Linking ReagentAnalytical Chemistry, 2011
- Excite-Coupled Trapping Ring Electrode Cell (eTREC): Radial Trapping Field Control, Linearized Excitation, And Improved DetectionAnalytical Chemistry, 2010
- A novel fourier transform ion cyclotron resonance mass spectrometer with improved ion trapping and detection capabilitiesJournal of the American Society for Mass Spectrometry, 2009
- The spontaneous loss of coherence catastrophe in fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 2009
- An Integrated, Directed Mass Spectrometric Approach for In-depth Characterization of Complex Peptide MixturesMolecular & Cellular Proteomics, 2008
- An electrically compensated trap designed to eighth order for FT-ICR mass spectrometryJournal of the American Society for Mass Spectrometry, 2008
- A low-noise, wideband preamplifier for a fourier-transform ion cyclotron resonance mass spectrometerJournal of the American Society for Mass Spectrometry, 2007
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998