Microfluidic-Integrated Multimodal Wearable Hybrid Patch for Wireless and Continuous Physiological Monitoring
Authors:
- 27 July 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (8) , 2960-2974
Abstract
Despite extensive advances in wearable monitoring systems, most designs focus on the detection of physical parameters or metabolites and do not consider the integration of microfluidic channels, miniaturization, and multimodality. In this study, a combination of multimodal (biochemical and electrophysiological) biosensing and microfluidic channel-integrated patch-based wireless systems is designed and fabricated using flexible materials for improved wearability, ease of operation, and real-time and continuous monitoring. The reduced graphene oxide-based microfluidic channel-integrated glucose biosensor exhibits a good sensitivity of 19.97 (44.56 without fluidic channels) μA mM-1 cm-2 within physiological levels (10 μM-0.4 mM) with good long-term and bending stability. All the sensors in the patch are initially validated using sauna gown sweat-based on-body and real-time tests with five separate individuals who perspired three times each. Multimodal glucose and electrocardiogram (ECG) sensing, along with their real-time adjustment based on sweat pH and temperature fluctuations, optimize sensing accuracy. Laser-burned hierarchical MXene-polyvinylidene fluoride-based conductive carbon nanofiber-based dry ECG electrodes exhibit low skin contact impedance (40.5 kΩ cm2) and high-quality electrophysiological signals (signal-to-noise ratios = 23.4-32.8 dB). The developed system is utilized to accurately and wirelessly monitor the sweat glucose and ECG of a human subject engaged in physical exercise in real time.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2017M3A9F1031270, NRF-2020R1A2C2012820)
This publication has 33 references indexed in Scilit:
- A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pHACS Nano, 2016
- A wearable chemical–electrophysiological hybrid biosensing system for real-time health and fitness monitoringNature Communications, 2016
- Wearable Chemical Sensors: Present Challenges and Future ProspectsACS Sensors, 2016
- Tunable dielectric properties in polyacrylonitrile/multiwall carbon nanotube compositesPolymer Composites, 2015
- Simultaneous determination of dopamine and uric acid in the presence of ascorbic acid using Pt nanoparticles supported on reduced graphene oxideElectrochimica Acta, 2014
- Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoringThe Analyst, 2012
- Hydrogen peroxide electrochemistry on platinum: towards understanding the oxygen reduction reaction mechanismPhysical Chemistry Chemical Physics, 2012
- CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG MonitoringIEEE Transactions on Biomedical Engineering, 2012
- Edge-plane microwire electrodes for highly sensitive H2O2 and glucose detectionBiosensors and Bioelectronics, 2011
- Electrochemistry of Individual Monolayer Graphene SheetsACS Nano, 2011