Magnetic Resonance Imaging of Prostate Cancer
Authors:
- Jin YamamuraJYJin Yamamura
- Georg SalomonGSGeorg Salomon
- Ralph BuchertRBRalph Buchert
- Arne HohensteinAHArne Hohenstein
- Joachim GraessnerJGJoachim Graessner
- Hartwig HulandHHHartwig Huland
- Markus GraefenMGMarkus Graefen
- Gerhard AdamGAGerhard Adam
- Ulrike WedegaertnerUWUlrike Wedegaertner
- 1 March 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 35 (2) , 223-228
Abstract
To retrospectively evaluate the impact of diffusion-weighted imaging (DWI) on the detection of prostate cancer in comparison with sextant biopsy. Fifty patients with clinical suspicion of prostate cancer underwent a combined endorectal-body-phased array magnetic resonance imaging examination at a 1.5 T magnetic resonance imaging (Siemens, Erlangen, Germany). The DWI was performed using b values of 50, 400, 800 s/mm2. The prostate was divided into sextants, including the apex, the middle aspect, and the base for the left and right sides, separately. Regions of interest were placed in the peripheral zone of each sextant to evaluate the apparent diffusion coefficient (ADC) values. The results of the DWI were compared side by side with the findings of the histological examination of endorectal sonographically guided sextant biopsy. The sensitivity and specificity of ADC for the identification of the tumor tissue were computed for variable discrimination thresholds to evaluate its receiver operating characteristic. An association between ADC and Gleason score was tested for both the whole study group and on an individual basis using the nonparametric Spearman ρ test and the Pearson correlation, respectively. Histopathology identified tumor tissue in 21 (42%) of the 50 patients. The ADC value was 1.65 ± 0.32 mm2/s 10−3 in normal tissue and 0.96 ± 0.24 mm2/s 10−3 in tumor tissue (mean ± 1 SD). The area under the receiver operating characteristic curve was 0.966. Using the discrimination threshold 1.21 mm2/s 10−3, for example, the ADC value provided a sensitivity of 0.92 and a specificity of 0.93. There was a highly significant negative correlation between the ADC value and the Gleason score in the tumor-positive tissue probes (n = 62, ρ = −0.405, P = 0.001) in the whole study group. On the individual patient basis, the Pearson correlation revealed a mean coefficient of r = −0.89 (SD ± 0.12) with a P < 0.001. Diffusion-weighted imaging of the prostate can be used to differentiate benign from malignant tissue in the peripheral zone. In the present study, ADC values were significantly lower in prostate cancer than in benign tissue.Keywords
This publication has 30 references indexed in Scilit:
- Lung Carcinoma: Diffusion-weighted MR Imaging—Preliminary Evaluation with Apparent Diffusion CoefficientRadiology, 2007
- Cancer Statistics, Trends, and Multiple Primary Cancer Analyses from the Surveillance, Epidemiology, and End Results (SEER) ProgramThe Oncologist, 2007
- Histopathologische Qualität von Prostatastanzzylindern: Vergleich einer MR-kompatiblen Biopsienadel mit einer im Ultraschall eingesetzten ferromagnetischen BiopsienadelRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2006
- Diffusion-Weighted Imaging of Prostate CancerJournal of Computer Assisted Tomography, 2005
- Leveling of prostate cancer mortality in Western EuropeThe Prostate, 2004
- Imaging clinically localized prostate cancerUrologic Clinics of North America, 2003
- Evaluation of Liver Diffusion Isotropy and Characterization of Focal Hepatic Lesions with Two Single-Shot Echo-planar MR Imaging Sequences: Prospective Study in 66 PatientsRadiology, 2003
- Diffusion-Weighted Echoplanar MR Imaging of the Salivary GlandsAmerican Journal of Roentgenology, 2002
- Three-dimensional H-1 MR spectroscopic imaging of the in situ human prostate with high (0.24-0.7-cm3) spatial resolution.Radiology, 1996
- Proton NMR relaxation times of experimental Lewis lung carcinoma after irradiationRadiotherapy and Oncology, 1988