Stacked Transistor Bias Circuit of Class-B Amplifier for Portable Ultrasound Systems
Author:
Open Access
Abstract
The performance of portable ultrasound systems is affected by the excessive heat generated by amplifiers, thereby reducing the sensitivity and resolution of the transducer devices used in ultrasound systems. Therefore, the amplifier needs to generate low amounts of heat to stabilize portable ultrasound systems. To properly control the amplifier, the related bias circuit must provide proper DC bias voltages for long time periods in ultrasound systems. To this end, a stacked transistor bias circuit was proposed to achieve a relatively constant amplifier performance irrespective of temperature variance without any cooling systems as the portable ultrasound system structure is limited. To prove the proposed concept, the performance of the gain and DC current consumption at different experimental times was measured and compared to a developed class-B amplifier with different bias circuits. The amplifier with the stacked transistor bias circuit outperformed with regard to the gain and DC current variance versus time (−0.72 dB and 0.065 A, respectively) compared to the amplifier with a typical resistor divider bias circuit (−5.27 dB and 0.237 A, respectively) after a certain time (5 min). Consequently, the proposed stacked transistor bias circuit is a useful electronic device for portable ultrasound systems with limited structure sizes because of its relatively low gain and DC current variance with respect to time.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2017R1C1B1003606)
This publication has 21 references indexed in Scilit:
- Bias-Voltage Stabilizer for HVHF Amplifiers in VHF Pulse-Echo Measurement SystemsSensors, 2017
- Driving an inductive piezoelectric transducer with class E inverterSensors and Actuators A: Physical, 2017
- Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo InstrumentationSensors, 2017
- A Wideband High-Voltage Power Amplifier Post-Linearizer for Medical Ultrasound TransducersApplied Sciences, 2017
- Development of a Double-Gauss Lens Based Setup for Optoacoustic ApplicationsSensors, 2017
- An impedance measurement system for piezoelectric array element transducersMeasurement, 2017
- Driving frequency optimization of a piezoelectric transducer and the power supply developmentReview of Scientific Instruments, 2016
- Class-DE Ultrasound Transducer Driver for HIFU TherapyIEEE Transactions on Biomedical Circuits and Systems, 2015
- Thermal-independent properties of PIN-PMN-PT single-crystal linear-array ultrasonic transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- Point-of-Care UltrasonographyNew England Journal of Medicine, 2011