A Comparison of a Traditional and Wavefront Autorefraction
Authors:
- 1 October 2014
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 91 (10) , 1191-1198
Abstract
Purpose: To evaluate the agreement between the autorefraction function of the Canon RK‐F2, an autorefractor/keratometer based on the ray deflection principle, and the Carl Zeiss Vision i.Profiler Plus , an wavefront aberrometer, compared with each other and with a noncycloplegic subjective refraction. Methods: Objective refraction results obtained using both instruments were compared with noncycloplegic subjective refractions for 174 eyes of 100 participants. Analysis of sphere, cylinder, and axis using spherical equivalent difference and a new measurement, cross‐cylinder difference, was performed. The spherical equivalent refraction and cross‐cylinder difference for the manifest refraction were compared using Bland‐Altman limits of agreement and 95th percentile analysis. Results: The 100 participants represent 52 women and 48 men with a mean (±SD) age of 51.7 (±13.8) years, an average (±SD) spherical power of −0.67 (±2.53) diopters (D), and an average (±SD) cylinder power of −0.94 (±0.87) D. The spherical equivalent difference is 0.03 D (Canon) and −0.11 D (Zeiss). The 95% limits of agreement for the spherical equivalent are −0.69 to 0.75 D (Canon) and −0.75 to 0.75 D (Zeiss). The mean cross‐cylinder power difference is −0.08 D (Canon) and 0.02 D (Zeiss). The 95% limits of agreement for the cross‐cylinder power difference are 0.63 to 0.50 D (Canon) and 0.49 to 0.75 D (Zeiss). The mean axis power difference is −0.04 D (Canon) and 0.05 D (Zeiss). The 95% limits of agreement for axis power difference are −0.71 to 0.63 D (Canon) and −0.78 to 0.78 D (Zeiss). The double‐angle astigmatic plot center of distribution for the RK‐F2 is 0.035 D at 70 degrees, and that for the i.Profiler Plus is 0.053 D at 32 degrees. Conclusions: Both instruments provided clinically useful spherical equivalent refractive data compared with a subjective refraction, whereas the Canon RK‐F2 was slightly more accurate in determining the cylinder power compared with a subjective refraction.Keywords
This publication has 28 references indexed in Scilit:
- Evaluation of the auto‐refraction function of the Nidek OPD‐Scan IIIClinical and Experimental Optometry, 2014
- Theoretical analysis of wavefront aberration caused by treatment decentration and transition zone after custom myopic laser refractive surgeryJournal of Cataract & Refractive Surgery, 2013
- Determining Spherocylindrical Correction Using Four Different Wavefront Error Analysis Methods: Comparison to Manifest RefractionJournal of Refractive Surgery, 2010
- Diagnostic accuracy and variability of autorefraction by the Tracey Visual Function Analyzer and the Shin‐Nippon NVision‐K 5001 in relation to subjective refractionOphthalmic and Physiological Optics, 2009
- The Precision of Wavefront Refraction Compared to Subjective Refraction and AutorefractionOptometry and Vision Science, 2007
- Accuracy, Repeatability, and Clinical Application of Spherocylindrical Automated Refraction Using Time-Based Wavefront Aberrometry MeasurementsOphthalmology, 2006
- A Comparison of Autorefractor PerformanceOptometry and Vision Science, 2004
- Validation of a Clinical Shack-Hartmann AberrometerOptometry and Vision Science, 2003
- Measurement of Refractive Errors in Young Myopes Using the COAS Shack-Hartmann AberrometerOptometry and Vision Science, 2003
- Clinical evaluation of the Allergan Humphrey 500 autorefractor and the Nidek AR-1000 autorefractor.British Journal of Ophthalmology, 1996