Influence of tomographic and biomechanical corneal indexes on myopic refractive surgery indications: A multicenter study
- 9 November 2021
- journal article
- research article
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 32 (5) , 2630-2637
Abstract
Purpose: To evaluate the influence of corneal tomographic and biomechanical indexes on the refractive technique indication. Methods: A total of 251 eyes from 251 patients interested in refractive surgery were enrolled in this cross-sectional and multicenter study. Previous to the surgeon decision, a preoperative protocol was performed by refractive optometrists, containing four sections: refraction, biometry, corneal tomography and biomechanics. The refractive surgeons made a first decision based only on refraction, biometric and tomographic information. Biomechanical indexes were revealed, and refractive surgeons made a second indication. Additionally, for Laser-Assisted in-situ Keratomileusis cases, the percent tissue altered were calculated. Possible indications were no refractive surgery, photorefractive keratectomy, Laser-Assisted in-situ Keratomileusis or intraocular Collamer lens. Results: After the first surgery indication, the distribution was photorefractive keratectomy (47.4%), Laser-Assisted in-situ Keratomileusis (48.2%) while intraocular Collamer lens achieved 2.8%. This proportion changed significantly after the second indication regarding corneal biomechanics and photorefractive keratectomy and Laser-Assisted in-situ Keratomileusis decreased by 24% while intraocular Collamer lens increased 19%. A total of 69 eyes changed the indication (27.5%) and 182 eyes (72.5%) remained unchanged. All indications changes were from photorefractive keratectomy or Laser-Assisted in-situ Keratomileusis to intraocular Collamer lens or no surgery. Indication changes to intraocular Collamer lens were observed in 49 eyes (71%). Tomographic, biomechanical indexes, ablation depth and percent tissue altered achieved statistically significant differences between eyes without and with indication changes (all, P < .01). Conclusion: New corneal biomechanical indexes could change the indication decision regarding biometric and tomographic data alone. Intraocular Collamer len was the preferred indication for eyes at risk of ectasia or with subclinical keratoconus due to corneal biomechanical parameters.Keywords
This publication has 32 references indexed in Scilit:
- Association Between the Percent Tissue Altered and Post–Laser In Situ Keratomileusis Ectasia in Eyes With Normal Preoperative TopographyAmerican Journal of Ophthalmology, 2014
- Biomechanics of corneal ectasia and biomechanical treatmentsJournal of Cataract & Refractive Surgery, 2014
- Changes in custom biomechanical variables after femtosecond laser in situ keratomileusis and photorefractive keratectomy for myopiaJournal of Cataract & Refractive Surgery, 2014
- Eight-Year Follow-up of Posterior Chamber Phakic Intraocular Lens Implantation for Moderate to High MyopiaAmerican Journal of Ophthalmology, 2014
- Long-term observation and evaluation of femtosecond laser–assisted thin-flap laser in situ keratomileusis in eyes with thin corneas but normal topographyJournal of Cataract & Refractive Surgery, 2014
- Long-term comparison of laser in situ keratomileusis versus laser surface ablation in corneas thinner than 470 μmJournal of Cataract & Refractive Surgery, 2012
- Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential ComplicationsJournal of Refractive Surgery, 2011
- Validation of the Ectasia Risk Score System for Preoperative Laser In Situ Keratomileusis ScreeningAmerican Journal of Ophthalmology, 2008
- Risk Assessment for Ectasia after Corneal Refractive SurgeryOphthalmology, 2008
- Photorefractive keratectomy: A technique for laser refractive surgeryJournal of Cataract & Refractive Surgery, 1988