A cross‐sectional comparison of three guidelines for intrapartum cardiotocography
Authors:
- 19 April 2017
- journal article
- research article
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 138 (1) , 89-93
Abstract
Objective: To compare the cardiotocography classification systems outlined by the International Federation of Gynecology and Obstetrics (FIGO) in 2015 and the UK National Institute for Health and Care Excellence (NICE) in 2007 and 2014.Methods: A cross‐sectional observational study of cardiotocography practices at a UK hospital was conducted among labor ward staff (n=21) from November 1 to November 31, 2015. All observers classified ten cardiotocography traces according to the three guidelines using a bespoke form. Outcome measures included interobserver agreement (κ values), percentage agreement, intervention rate, and perceived ease of use.Results: The κ values were 0.38 (FIGO 2015), 0.37 (NICE 2007), and 0.34 (NICE 2014). The percentage agreement was identical across the three systems for both normal cardiotocography results (100.0%) and for intermediate or suspicious results (80.9%). By contrast, the percentage agreement for abnormal or pathological findings was 47.6% for NICE 2014, 76.2% for FIGO 2015, and 91.0% for NICE 2007 guidelines. Among 210 observations, intervention was deemed necessary for 48 (22.9%) for FIGO 2015, 29 (13.8%) for NICE 2014, and 56 (26.7%) for NICE 2007 guidelines. The FIGO 2015 system was considered the easiest to use by 13 (61.9%) observers.Conclusion: Interobserver agreement of cardiotocography classification is suboptimal. The FIGO 2015 system offered favorable agreement scores, perceived ease of use, and a moderate intervention rate.Keywords
This publication has 23 references indexed in Scilit:
- ST Analysis of the Fetal Electrocardiogram in Intrapartum Fetal MonitoringObstetrics & Gynecology, 2012
- Perinatal and maternal outcomes by planned place of birth for healthy women with low risk pregnancies: the Birthplace in England national prospective cohort studyBMJ, 2011
- A randomised clinical trial of intrapartum fetal monitoring with computer analysis and alerts versus previously available monitoringBMC Pregnancy and Childbirth, 2010
- Inter‐ and intra‐observer agreement of intrapartum ST analysis of the fetal electrocardiogram in women monitored by STANBJOG: An International Journal of Obstetrics & Gynaecology, 2009
- The 2008 National Institute of Child Health and Human Development Workshop Report on Electronic Fetal Monitoring: Update on Definitions, Interpretation, and Research GuidelinesJournal of Obstetric, Gynecologic, & Neonatal Nursing, 2008
- Midwives’ visual interpretation of intrapartum cardiotocographs: intra‐ and inter‐observer agreementJournal of Advanced Nursing, 2005
- Inconsistencies in classification by experts of cardiotocograms and subsequent clinical decisionBJOG: An International Journal of Obstetrics & Gynaecology, 1999
- Antenatal antecedents of moderate and severe cerebral palsyPaediatric and Perinatal Epidemiology, 1995
- The fetal heart rate trace is normal, isn't it?The Lancet, 1991
- THE SIGNIFICANCE OF THE CHANGES IN THE CONTINUOUS FETAL HEART RATE IN THE FIRST STAGE OF LABOURBJOG: An International Journal of Obstetrics & Gynaecology, 1971