Impact of Different Screw Designs on Durability of Fracture Fixation: In Vitro Study with Cyclic Loading of Scaphoid Bones
Authors:
Open Access
- 7 January 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (1) , e0145949
Abstract
The use of new headless compression screws (HCSs) for scaphoid fixation is growing, but the nonunion rate has remained constant. The aim of this study was to compare the stability of fixation resulting from four modern HCSs using a simulated fracture model to determine the optimal screw design(s). We tested 40 fresh-frozen cadaver scaphoids treated with the Acumed Acutrak 2 mini (AA), the KLS Martin HBS2 midi (MH), the Stryker TwinFix (ST) and the Synthes HCS 3.0 with a long thread (SH). The bones with simulated fractures and implanted screws were loaded uniaxially into flexion for 2000 cycles with a constant bending moment of 800 Nmm. The angulation of the fracture fragments was measured continuously. Data were assessed statistically using the univariate ANOVA test and linear regression analysis, and the significance level was set at p < 0.05. The median angulation of bone fragments φ allowed by each screw was 0.89° for AA, 1.12° for ST, 1.44° for SH and 2.36° for MH. With regards to linear regression, the most reliable curve was achieved by MH, with a coefficient of determination of R2 = 0.827. This was followed by AA (R2 = 0.354), SH (R2 = 0.247) and ST (R2 = 0.019). Data assessed using an adapted ANOVA model showed no statistically significant difference (p = 0.291) between the screws. The continuous development of HCSs has resulted in very comparable implants, and thus, at this time, other factors, such as surgeons’ experience, ease of handling and price, should be taken into consideration.Keywords
This publication has 36 references indexed in Scilit:
- A Comparison of 2 Methods for Scaphoid Central Screw Placement From a Volar ApproachThe Journal of Hand Surgery, 2011
- A comparison of two headless compression screws for operative treatment of scaphoid fracturesJournal of Orthopaedic Surgery and Research, 2011
- Influence of formalin fixation on the biomechanical properties of human diaphyseal boneBiomedical Engineering / Biomedizinische Technik, 2010
- A Computational Approach to the “Optimal” Screw Axis Location and Orientation in the Scaphoid BoneThe Journal of Hand Surgery, 2009
- Treatment of Scaphoid Fractures and NonunionsThe Journal of Hand Surgery, 2008
- Percutaneous screw fixationversusconservative treatment for fractures of the waist of the scaphoidThe Journal of Bone and Joint Surgery. British volume, 2008
- Retrograde (Volar) Scaphoid Screw Insertion—A Quantitative Computed Tomographic AnalysisThe Journal of Hand Surgery, 2005
- Interfragmentary compression across a simulated scaphoid fracture—analysis of 3 screwsThe Journal of Hand Surgery, 2004
- Shear movement at the fracture site delays healing in a diaphyseal fracture modelJournal of Orthopaedic Research, 2003
- Acutrak Screw Fixation Versus Cast Immobilisation for Undisplaced Scaphoid Waist FracturesJournal of Hand Surgery (European Volume), 2001