Improved precision and accuracy for high‐performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometric exact mass measurement of small molecules from the simultaneous and controlled introduction of internal calibrants via a second electrospray nebuliser
- 15 November 2004
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (24) , 3035-3040
Abstract
The use of a second electrospray nebuliser has proved to be highly successful for exact mass measurement during high‐performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry (HPLC/FTICRMS). Much improved accuracy and precision of mass measurement were afforded by the introduction of the internal calibration solution, thus overcoming space charge issues due to the lack of control over relative ion abundances of the species eluting from the HPLC column. Further, issues of suppression of ionisation, observed when using a T‐piece method, are addressed and this simple system has significant benefits over other more elaborate approaches providing data that compares very favourably with these other approaches. The technique is robust, flexible and transferable and can be used in conjunction with HPLC, infusion or flow injection analysis (FIA) to provide constant internal calibration signals to allow routine, accurate and precise mass measurements to be recorded. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 13 references indexed in Scilit:
- An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomicsJournal of the American Society for Mass Spectrometry, 2004
- Intercomparison study on accurate mass measurement of small molecules in mass spectrometryJournal of the American Society for Mass Spectrometry, 2003
- Space charge effects on mass accuracy for multiply charged ions in ESI–FTICRInternational Journal of Mass Spectrometry, 2003
- Peer Reviewed: Scaling MS Plateaus with High-Resolution FT-ICRMSAnalytical Chemistry, 2002
- Internal Calibration on Adjacent Samples (InCAS) with Fourier Transform Mass SpectrometryAnalytical Chemistry, 2000
- Broad-Band Ion Accumulation with an Internal Source MALDI-FTICR-MSAnalytical Chemistry, 2000
- A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in Fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 2000
- Exact mass measurements using a 7 tesla fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environmentJournal of the American Society for Mass Spectrometry, 1999
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Fourier Transform Mass SpectrometryJournal of Mass Spectrometry, 1996