Reproducibility of Aorta Segmentation on 4D Flow MRI in Healthy Volunteers
Open Access
- 11 November 2020
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 53 (4) , 1268-1279
Abstract
Background: Hemodynamic aorta parameters can be derived from 4D flow MRI, but this requires lumen segmentation. In both commercially available and research 4D flow MRI software tools, lumen segmentation is mostly (semi‐)automatically performed and subsequently manually improved by an observer. Since the segmentation variability, together with 4D flow MRI data and image processing algorithms, will contribute to the reproducibility of patient‐specific flow properties, the observer's lumen segmentation reproducibility and repeatability needs to be assessed.Purpose: To determine the interexamination, interobserver reproducibility, and intraobserver repeatability of aortic lumen segmentation on 4D flow MRI.Study Type: Prospective and retrospective.Population: A healthy volunteer cohort of 10 subjects who underwent 4D flow MRI twice. Also, a clinical cohort of six subjects who underwent 4D flow MRI once.Field Strength/Sequence: 3T; time‐resolved three‐directional and 3D velocity‐encoded sequence (4D flow MRI).Assessment: The thoracic aorta was segmented on the 4D flow MRI in five systolic phases. By positioning six planes perpendicular to a segmentation's centerline, the aorta was divided into five segments. The volume, surface area, centerline length, maximal diameter, and curvature radius were determined for each segment.Statistical Tests: To assess the reproducibility, the coefficient of variation (COV), Pearson correlation coefficient (r), and intraclass correlation coefficient (ICC) were calculated.Results: The interexamination and interobserver reproducibility and intraobserver repeatability were comparable for each parameter. For both cohorts there was very good reproducibility and repeatability for volume, surface area, and centerline length (COV = 10–32%, r = 0.54–0.95 and ICC = 0.65–0.99), excellent reproducibility and repeatability for maximal diameter (COV = 3–11%, r = 0.94–0.99, ICC = 0.94–0.99), and good reproducibility and repeatability for curvature radius (COV = 25–62%, r = 0.73–0.95, ICC = 0.84–0.97).Data Conclusion: This study demonstrated no major reproducibility and repeatability limitations for 4D flow MRI aortic lumen segmentation.Level of Evidence: 3Technical Efficacy Stage: 2Keywords
Funding Information
- Hartstichting (CVON2017‐08‐RADAR)
This publication has 33 references indexed in Scilit:
- Assessment of the accuracy of MRI wall shear stress estimation using numerical simulationsJournal of Magnetic Resonance Imaging, 2012
- Reproducibility of flow and wall shear stress analysis using flow‐sensitive four‐dimensional MRIJournal of Magnetic Resonance Imaging, 2011
- In vivo three‐dimensional MR wall shear stress estimation in ascending aortic dilatationJournal of Magnetic Resonance Imaging, 2011
- Thoracic Aortic AneurysmJACC, 2010
- Three‐dimensional analysis of segmental wall shear stress in the aorta by flow‐sensitive four‐dimensional‐MRIJournal of Magnetic Resonance Imaging, 2009
- Hemodynamic shear stress and the endothelium in cardiovascular pathophysiologyNature Clinical Practice Cardiovascular Medicine, 2008
- Aneurysm Growth Occurs at Region of Low Wall Shear StressStroke, 2008
- Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parametersMagnetic Resonance in Medicine, 2008
- Intra- and Interobserver Variability of Aortic Aneurysm Volume Measurement With Fast CTA Postprocessing SoftwareJournal of Endovascular Therapy, 2008
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986