Reexamination of Accelerometer Calibration with Energy Expenditure as Criterion: VO2net Instead of MET for Age-Equivalent Physical Activity Intensity
Open Access
Abstract
Accelerometer calibration for physical activity (PA) intensity is commonly performed using Metabolic Equivalent of Task (MET) as criterion. However, MET is not an age-equivalent measure of PA intensity, which limits the use of MET-calibrated accelerometers for age-related PA investigations. We investigated calibration using VO2net (VO2gross − VO2stand; mL⋅min−1⋅kg−1) as criterion compared to MET (VO2gross/VO2rest) and the effect on assessment of free-living PA in children, adolescents and adults. Oxygen consumption and hip/thigh accelerometer data were collected during rest, stand and treadmill walk and run. Equivalent speed (Speedeq) was used as indicator of the absolute speed (Speedabs) performed with the same effort in individuals of different body size/age. The results showed that VO2net was higher in younger age-groups for Speedabs, but was similar in the three age-groups for Speedeq. MET was lower in younger age-groups for both Speedabs and Speedeq. The same VO2net-values respective MET-values were applied to all age-groups to develop accelerometer PA intensity cut-points. Free-living moderate-and-vigorous PA was 216, 115, 74 and 71 min/d in children, adolescents, younger and older adults with VO2net-calibration, but 140, 83, 74 and 41 min/d with MET-calibration, respectively. In conclusion, VO2net calibration of accelerometers may provide age-equivalent measures of PA intensity/effort for more accurate age-related investigations of PA in epidemiological research.Keywords
This publication has 32 references indexed in Scilit:
- A Critical Review of the History of Low- to Moderate-Intensity Steady-State VO2 KineticsSports Medicine, 2014
- Calibration and Validation of Wearable MonitorsMedicine & Science in Sports & Exercise, 2012
- Quantity and Quality of Exercise for Developing and Maintaining Cardiorespiratory, Musculoskeletal, and Neuromotor Fitness in Apparently Healthy AdultsMedicine & Science in Sports & Exercise, 2011
- Comparison of Accelerometer Cut Points for Predicting Activity Intensity in YouthMedicine & Science in Sports & Exercise, 2011
- The mass-specific energy cost of human walking is set by statureJournal of Experimental Biology, 2010
- Equivalence of accelerometer data for walking and running: Treadmill versus on landJournal of Sports Sciences, 2009
- Physical Activity in the United States Measured by AccelerometerMedicine & Science in Sports & Exercise, 2008
- The Size-Independent Oxygen Cost of RunningMedicine & Science in Sports & Exercise, 2003
- Effect of Monitor Placement and of Activity Setting on the MTI Accelerometer OutputMedicine & Science in Sports & Exercise, 2003