Effect of accelerated corneal crosslinking combined with transepithelial photorefractive keratectomy on dynamic corneal response parameters and biomechanically corrected intraocular pressure measured with a dynamic Scheimpflug analyzer in healthy myopic patients
Authors:
- Hun LeeHLHun Lee
- Cynthia J. RobertsCRCynthia J. Roberts
- Renato AmbrósioRARenato Ambrósio
- Ahmed ElsheikhAhmed Elsheikh
- David Sung Yong KangDKDavid Sung Yong Kang
- Tae-Im KimTKTae-Im Kim
- 1 July 2017
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 43 (7) , 937-945
Abstract
To evaluate the effect of accelerated corneal crosslinking (CXL) combined with transepithelial photorefractive keratectomy (PRK) on changes in new dynamic corneal response parameters and the biomechanically corrected intraocular pressure (IOP) measured using a dynamic Scheimpflug analyzer (Corvis ST). Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. Retrospective case series. Medical records of eyes of healthy myopic patients having transepithelial PRK or transepithelial PRK with CXL were examined. Main outcome variables were the biomechanically corrected IOP and new dynamic corneal response parameters including the deformation amplitude ratio at 1.0 mm (DAR1) and at 2.0 mm (DAR2), stiffness at first applanation and at highest concavity, and the integrated inverse radius preoperatively and 6 months postoperatively. The study comprised 69 eyes (69 patients); 35 had transepithelial PRK and 34, transepithelial PRK with CXL. The DAR1, DAR2, and integrated inverse radius significantly increased, while stiffness at first applanation and at highest concavity decreased postoperatively in both groups. Changes in the DAR2 and integrated inverse radius in the transepithelial PRK group were significantly larger than in the transepithelial PRK with CXL group without and with analysis of covariance with the spherical equivalent change or corneal thickness change as a covariate. No significant differences in the biomechanically corrected IOP occurred preoperatively or postoperatively in either group. Results indicate that prophylactic CXL combined with transepithelial PRK has a role in reducing the change in corneal biomechanical properties. The dynamic Scheimpflug analyzer showed stable biomechanically corrected IOP measurements preoperatively and postoperatively.Keywords
This publication has 15 references indexed in Scilit:
- Introduction of Two Novel Stiffness Parameters and Interpretation of Air Puff–Induced Biomechanical Deformation Parameters With a Dynamic Scheimpflug AnalyzerJournal of Refractive Surgery, 2017
- Development and validation of a correction equation for Corvis tonometryComputer Methods in Biomechanics and Biomedical Engineering, 2015
- Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globesExperimental Eye Research, 2015
- Ocular Biomechanical Metrics by CorVis ST in Healthy Brazilian PatientsJournal of Refractive Surgery, 2014
- Accelerated versus conventional corneal collagen crosslinkingJournal of Cataract & Refractive Surgery, 2014
- Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometryGraefe's Archive for Clinical and Experimental Ophthalmology, 2014
- Comparison of Corneal Deformation Parameters After SMILE, LASEK, and Femtosecond Laser-Assisted LASIKJournal of Refractive Surgery, 2014
- Corneal Biomechanics as a Function of Intraocular Pressure and Pachymetry by Dynamic Infrared Signal and Scheimpflug Imaging Analysis in Normal EyesAmerican Journal of Ophthalmology, 2014
- Multiparameter Correction Equation for Goldmann Applanation TonometryOptometry and Vision Science, 2011
- Finite Element Modeling of Corneal Biomechanical BehaviorJournal of Refractive Surgery, 2010