Non‐invasive tear break‐up time in normal Malays
Authors:
- Tan Choon BayTBTan Choon Bay
- Maurice YapMYMaurice Yap
- 1 January 2002
- journal article
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 85 (1) , 37-41
Abstract
Background: Tear stability in normal Malays with consideration of gender and age has not been reported. In this study, we measured tear stability in normal Malays using the non‐invasive tear break‐up time (NIBUT). Methods: Forty‐eight Malay subjects aged seven to 60 years were recruited from among the staff, their children and students of the faculty. NIBUT was measured by noting the time taken for distortions to appear in a reflected image of a grid pattern formed on the corneal surface. Results: The mean NIBUT of the sample was 15.8 ± 9.4 (SD) seconds. The median was 14.6 seconds with range of 4.2 seconds to 48.6 seconds. The majority (73 per cent) of subjects had NIBUT values between six and 20 seconds. There was no significant difference in NIBUT values between males and females but there was a decrease of NIBUT with age. Conclusion: The NIBUT values found in this study are comparable to those reported for Asian populations but much less than those of Western populations. Our findings point to the need for local clinical studies in contact lens and contact lens‐related research as tear physiology of the local population may not be the same as in Western populations.Keywords
This publication has 14 references indexed in Scilit:
- The Relation between Invasive and Noninvasive Tear Break-Up TimeOptometry and Vision Science, 1995
- Inter‐ and intra‐individual variability of non‐invasive tear break‐up time in Hong Kong ChineseClinical and Experimental Optometry, 1994
- Reliability of a Portable Noninvasive Tear Break-Up Time Test on Hong Kong-ChineseOptometry and Vision Science, 1993
- Age, Gender, and Tear Break-Up TimeOptometry and Vision Science, 1993
- Designing contact lenses for oriental eyesJournal of The British Contact Lens Association, 1991
- Non-invasive assessment of tear film break-up time in a group of normal subjects - implications for contact lens wearJournal of The British Contact Lens Association, 1991
- Effects of Fluorescein on Tear Breakup Time and on Tear Thinning TimeOptometry and Vision Science, 1985
- A non-invasive instrument for clinical assessment of the pre-corneal tear film stabilityCurrent Eye Research, 1985
- Factors Affecting Tear Film Breakup in Normal EyesArchives of Ophthalmology (1950), 1973
- DESICCATION OF THE PRECORNEAL FILMActa Ophthalmologica, 1969