Spiral Computed Tomography
Authors:
- 8 September 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 98 (10) , 984-989
Abstract
Background —For the detection of atherosclerotic lesions of the extracranial cerebral arteries, duplex ultrasonography (US) is an established operator-dependent method, whereas arteriography is associated with the not-insignificant risk of embolic complications. Spiral CT is a promising novel diagnostic tool that allows noninvasive, operator-independent diagnosis of obstruction of extracranial cerebral arteries. The aim of our prospective study was to evaluate in a clinical setting the complementary role of duplex US and spiral CT. Methods and Results —We compared the results obtained independently by spiral CT and duplex US in 59 consecutive patients with clinical suspicion of an obstructive lesion affecting the carotid arteries. We analyzed a total of 354 segments from the extracranial carotid arteries, including the common, internal, and external carotid arteries. A total of 4 complete occlusions, 38 severe stenoses (70% to 99%), and 32 moderate stenoses (30% to 69%) were concordantly identified by means of duplex US and spiral CT. In 5 cases in which duplex US did not allow sufficient evaluation of the carotid artery because of a poor US window or severe calcification, spiral CT allowed identification and correct measurement of the stenotic lesion. The comparison of the percentage of stenosis with both methods was good ( r =0.91, P =0.024). Conclusions —Our results indicate that spiral CT of the extracranial cerebral arteries is a promising noninvasive complementary and non–operator-dependent examination. Its application is particularly attractive in cases in which duplex US is not reliable (ie, severe kinking, severe calcification, short neck, and high bifurcation) and particularly when an overall view of the vascular field is required.Keywords
This publication has 25 references indexed in Scilit:
- Carotid duplex criteria for a 60% or greater angiographic stenosis: Variation according to equipmentJournal of Vascular Surgery, 1996
- Validity of B-Mode Ultrasonographic Findings in Patients Undergoing Carotid Endarterectomy in Comparison With Angiographic and Clinicopathologic FeaturesStroke, 1996
- Determination of Duplex Doppler Ultrasound Criteria Appropriate to the North American Symptomatic Carotid Endarterectomy TrialStroke, 1996
- Prospective evaluation of new duplex criteria to identify 70% internal carotid artery stenosisJournal of Vascular Surgery, 1996
- Erste Ergebnisse der Spiral-CT-Angiographie beim Nachweis von Stenosen der A. carotisRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1995
- The role of duplex scanning and arteriography before carotid endarterectomy: A prospective studyJournal of Vascular Surgery, 1993
- Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters.American Journal of Roentgenology, 1993
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid StenosisNew England Journal of Medicine, 1991
- MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosisThe Lancet, 1991
- Cerebral angiographic risk in mild cerebrovascular disease.Stroke, 1990