On the Design of Passive Resonant Circuits to Measure Local Pulse Wave Velocity in a Stent
- 20 January 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 10 (3) , 612-622
Abstract
In-stent restenosis is a frequent complication after stent implantation. This article investigates the design of a passive sensor system to be integrated into a stent for the detection of an in-stent restenosis by measuring the local pulse wave velocity (PWV). The proposed system uses two resonant circuits consisting of a capacitive pressure sensor and a coil as transponders. The pressure sensors are located at the proximal and distal end of the stent. An alternating external magnetic field with a constant frequency is applied such that the resonance frequencies of the transponders cross the excitation frequency when the pulse wave passes. The time delay between the resonances at the transponders can be captured to obtain the PWV. A model for the measurement system and a correlation between transponder design parameters and minimal resolvable time delay are derived. This correlation is based on the criterion that the 3 dB bandwidth of the transponder resonances may not overlap in the measurement time interval. This correlation can be used to design and analyze a transponder system for the proposed measurement system. In an experiment, in which the pressure sensors have been emulated by varactor diodes, it could be shown that the model is valid and that the criterion is suitable. Finally, the relevant design parameters of the transponders have been identified and their limitations investigated.Keywords
This publication has 24 references indexed in Scilit:
- Implantable Flexible Pressure Measurement System Based on Inductive CouplingIEEE Transactions on Biomedical Engineering, 2014
- In vivo and in situ evaluation of a wireless magnetoelastic sensor array for plastic biliary stent monitoringBiomedical Microdevices, 2013
- Metglas–Elgiloy bi-layer, stent cell resonators for wireless monitoring of viscosity and mass loadingJournal of Micromechanics and Microengineering, 2012
- Restenosis after PCI. Part 2: prevention and therapyNature Reviews Cardiology, 2011
- Tailored magnetoelastic sensor geometry for advanced functionality in wireless biliary stent monitoring systemsJournal of Micromechanics and Microengineering, 2010
- In situ and ex vivo evaluation of a wireless magnetoelastic biliary stent monitoring systemBiomedical Microdevices, 2010
- Wireless Magnetoelastic Monitoring of Biliary StentsJournal of Microelectromechanical Systems, 2008
- Expert consensus document on arterial stiffness: methodological issues and clinical applicationsEuropean Heart Journal, 2006
- EM radiation behavior upon biological tissues in a radio-frequency power transfer link for a cortical visual implant2002
- The velocity of pulse wave in manProceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character, 1922