Cardiac Perforation From Implantable Cardioverter-Defibrillator Lead Placement
Authors:
- 1 September 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 6 (5) , 582-590
Abstract
Background—: Cardiac perforation is a feared complication of implantable cardioverter-defibrillator (ICD) lead implantation because of the potential for significant morbidity and mortality. Predictors of perforation and the severity of associated adverse events have not been well studied. We sought to identify predictors of cardiac perforation from ICD lead implantation and subsequent outcomes. Methods and Results—: We studied 440 251 first-time ICD recipients in the ICD Registry implanted between January 2006 and September 2011. Using hierarchical multivariable logistic regression adjusting for patient, implanting physician, and hospital characteristics, we examined the predictors of perforation and the association of perforation with other major complications, length of stay, and in-hospital mortality. Cardiac perforation occurred in 625 patients (0.14%). After multivariable adjustment, older age, female sex, left bundle branch block, worsened heart failure class, higher left ventricular ejection fraction, and non–single-chamber ICD implant were associated with a greater odds of perforation. Conversely, atrial fibrillation, diabetes mellitus, previous cardiac bypass surgery, and higher implanter procedural volume were associated with a lower odds of perforation (all P P 3 days (odds ratio, 16.3; 95% confidence interval, 13.7–19.4; P P <0.0001). Conclusions—: In a large population of ICD recipients, specific patient and implanter characteristics predicted cardiac perforation risk. Cardiac perforation was associated with a substantially increased risk of other major complications, prolonged hospital stays, and death.Keywords
This publication has 17 references indexed in Scilit:
- The National Cardiovascular Data Registry (NCDR) Data Quality BriefJACC, 2012
- Rates and severity of perforation from implantable cardioverter-defibrillator leads: A 4-year studyJournal of Interventional Cardiac Electrophysiology, 2008
- Review of the Registry's Second Year, Data Collected, and Plans to Add Lead and Pediatric ICD ProceduresHeart Rhythm, 2008
- Lead Perforation: Incidence in RegistriesPacing and Clinical Electrophysiology, 2007
- Prevalence and Characterization of Asymptomatic Pacemaker and ICD Lead Perforation on CTPacing and Clinical Electrophysiology, 2007
- Clinical competency statement: Training pathways for implantation of cardioverter defibrillators and cardiac resynchronization devicesHeart Rhythm, 2004
- Comparing hierarchical modeling with traditional logistic regression analysis among patients hospitalized with acute myocardial infarction: Should we be analyzing cardiovascular outcomes data differently?American Heart Journal, 2003
- Late Fatal Right Ventricular Perforation as Complication of Permanent Pacing LeadsPacing and Clinical Electrophysiology, 2001
- Incidence of Perforation and Other Mechanical Complications During Dual Active FixationPacing and Clinical Electrophysiology, 1996
- Complications of Permanent Transvenous Cardiac Pacing: A 14‐Year Review of all Transvenous Pacemakers Inserted at One Community HospitalPacing and Clinical Electrophysiology, 1987