The mechanical consequences of load bearing in the equine third metacarpal across speed and gait: the nonuniform distributions of normal strain, shear strain, and strain energy density
Authors:
Open Access
- 25 January 2013
- journal article
- research article
- Published by Wiley in The FASEB Journal
- Vol. 27 (5) , 1887-1894
Abstract
Distributions of normal strain, shear strain, and strain energy density (SED) were determined across the midshaft of the third metacarpal (MCIII, or cannon bone) of 3 adult thoroughbred horses as a function of speed and gait. A complete characterization of the mechanical demands of the bone made through the stride and from mild through the extremes of locomotion was possible by using three 3‐element rosette strain gauges bonded at the diaphyseal midshaft of the MCIII and evaluating the strain output with beam theory and finite element analysis. Mean ± sd values of normal strain, shear strain, and SED increased with speed and peaked during a canter (–3560 ±380 microstrain, 1760 ±470 microstrain, and 119±23 kPa, respectively). While the location of these peaks was similar across animals and gaits, the resulting strain distributions across the cortex were consistently nonuniform, establishing between a 73‐fold (slow trot) to a 330‐fold (canter) disparity between the sites of maximum and minimum SED for each gait cycle. Using strain power density as an estimate of strain history across the bone revealed a 154‐fold disparity between peak and minimum at the walk but fell to ~32‐fold at the canter. The nonuniform, minimally varying, strain environment suggests either that bone homeostasis is mediated by magnitude‐independent mechanical signals or that the duration of stimuli necessary to establish and maintain tissue integrity is relatively brief, and thus the vast majority of strain information is disregarded.—Rubin, C. T., Seeherman, H., Qin, Y.‐X., Gross, T. S., The mechanical consequences of load bearing in the equine third metacarpal across speed and gait: the nonuniform distributions of normal strain, shear strain, and strain energy density. FASEB J. 27, 1887–1894 (2013). www.fasebj.orgKeywords
Funding Information
- National Institutes of Health (AR‐49438, EB914351)
- Medical Research and Materiel Command
This publication has 34 references indexed in Scilit:
- The amazing osteocyteJournal of Bone and Mineral Research, 2010
- Variability in forelimb bone strains during non-steady locomotor activities in goatsJournal of Experimental Biology, 2008
- The anabolic activity of bone tissue, suppressed by disuse, is normalized by brief exposure to extremely low‐magnitude mechanical stimuliThe FASEB Journal, 2001
- Correlation of bony ingrowth to the distribution of stress and strain parameters surrounding a porous‐coated implantJournal of Orthopaedic Research, 1996
- Fatigue fractures in thoroughbred racehorses: Relationships with age, peak bone strain, and trainingJournal of Orthopaedic Research, 1990
- Bone remodeling of diaphyseal surfaces by torsional loads: Theoretical predictionsJournal of Biomechanics, 1987
- Functional strain in bone tissue as an objective, and controlling stimulus for adaptive bone remodellingJournal of Biomechanics, 1987
- Dynamic strain similarity in vertebrates; an alternative to allometric limb bone scalingJournal of Theoretical Biology, 1984
- Bone stress in the horse forelimb during locomotion at different gaits: A comparison of two experimental methodsJournal of Biomechanics, 1983
- Mechanical properties of bone tissues with greatly differing functionsJournal of Biomechanics, 1979