Clinical Validation of a Wearable Piezoelectric Blood‐Pressure Sensor for Continuous Health Monitoring
Authors:
Top Cited Papers
- 11 May 2023
- journal article
- research article
- Published by Wiley in Advanced Materials
- Vol. 35 (26) , e2301627
Abstract
Wearable blood‐pressure sensors have recently attracted attention as healthcare devices for continuous non‐invasive arterial pressure (CNAP) monitoring. However, the accuracy of wearable blood‐pressure (BP) monitoring devices has been controversial due to the low signal quality of sensors, the absence of an accurate transfer function to convert the sensor signals into BP values, and the lack of clinical validation regarding measurement precision. Here, a wearable piezoelectric blood‐pressure sensor (WPBPS) is reported, which achieves a high normalized sensitivity (0.062 kPa−1), and fast response time (23 ms) for CNAP monitoring. The transfer function of a linear regression model is designed, offering a simple solution to convert the flexible piezoelectric sensor signals into BP values. In order to verify the measurement accuracy of WPBPS, clinical trials are performed on 35 subjects aged from 20 to 80 s after screening. The mean difference between the WPBPS and a commercial sphygmomanometer of 175 BP data pairs is −0.89 ± 6.19 and −0.32 ± 5.28 mmHg for systolic blood pressure (SBP) and diastolic blood pressure (DBP), respectively. By building a WPBPS‐embedded wristwatch, the potentially promising use of a convenient, portable, continuous BP monitoring system for cardiovascular disease diagnosis is demonstrated.Keywords
Funding Information
- National Research Foundation of Korea
This publication has 46 references indexed in Scilit:
- Ambulatory blood pressure monitoring and development of cardiovascular events in high-risk patients included in the Spanish ABPM registryJournal Of Hypertension, 2012
- Ambulatory blood pressure monitoring in AustraliaJournal Of Hypertension, 2012
- Arterial AgingDrugs & Aging, 2011
- European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adultsBlood Pressure Monitoring, 2010
- Arterial blood pressure measurement and pulse wave analysis-–their role in enhancing cardiovascular assessmentPhysiological Measurement, 2009
- Age-specific relevance of usual blood pressure to vascular mortality: a meta-analysis of individual data for one million adults in 61 prospective studiesThe Lancet, 2002
- Pulse wave analysisBritish Journal of Clinical Pharmacology, 2001
- A New Model-Based Method of Reconstructing Central Aortic Pressure from Peripheral Arterial Pressure.The Japanese Journal of Physiology, 2001
- Noninvasive Assessment of the Digital Volume PulseHypertension, 2000
- Accuracy of a continuous blood pressure monitor based on arterial tonometry.Hypertension, 1993