Abstract
This paper delves into the enhancement of dynamic performance in Piezoelectric Micromachined Ultrasonic Transducers (PMUTs) under forced vibration in pulse wave mode, with an emphasis on mitigating blind area and enhancing axial resolution. The investigation begins with a theoretical framework that elucidates the relationship between the resonant frequency of the device and various excitation parameters, such as the applied frequency and the burst count. Empirical findings illustrate that the operation of PMUTs under forced vibration conditions significantly curtails the duration of ringdown by 40% compared to their resonant performance. Furthermore, acoustic range evaluations indicate that this methodology substantially reduces the blind area by 37.5% and amplifies the axial resolution of echo signals by approximately 440%. The study concludes that the proposed technique, noted for its universality and straightforwardness, provides a robust solution for enhancing near-range detection capabilities in ultrasonic sensors, thereby heralding considerable progress in the domain of precise acoustic measurements. This paper not only explicates the fundamental mechanisms but also substantiates the feasibility and efficacy of employing forced vibration in PMUT across diverse applications.
Funding Information
  • Gleen Howatt Electroceramic Laboratory, Department of Materials Science and Engineering, Rutgers University, NJ, USA
  • Shanghai Melon Tech. Inc., Shanghai, China

This publication has 24 references indexed in Scilit: