Deleterious Effects of Cardiac Pacing in a Patient with Mitral Insufficiency
Authors:
- 12 January 1977
- journal article
- research article
- Published by Wiley in Acta Medica Scandinavica
- Vol. 202 (1-6) , 331-334
Abstract
A 70 yr old, artificially paced woman with dizziness and extremely low physical capacity exhibited a systolic BP [blood pressure] varying from one moment to another; in standing position it was not measurable. With the aid of a strain gauge technique, the amplitude of the pulse wave of her left thumb was recorded and shown to vary widely. The variations were correlated to synchrony or asynchrony between atrial and ventricular activity. Pronounced decreases in stroke volume and peripheral pulse volume were recorded with pacemaker-induced beats compared with idioventricular beats. With artificial stimulation at a rate of 45/min, thus avoiding competition but still protecting her from syncopes, she was free from symptoms.Keywords
This publication has 8 references indexed in Scilit:
- HAEMODYNAMIC EFFECT OF ATRIAL TRIGGERED VERSUS FIXED RATE PACING AT REST AND DURING EXERCISE IN COMPLETE HEART BLOCKActa Medica Scandinavica, 1975
- Pacemaker-induced cardiovascular failureThe American Journal of Cardiology, 1974
- Effect of Changes in Ventricular Rate on Forearm Blood Flow and Systemic Arterial Pressure in Patients with Artificial PacemakersScandinavian Journal of Clinical and Laboratory Investigation, 1973
- Effect of atrial systole on right ventricular stroke output in complete heart block.BMJ, 1967
- Hemodynamic sequelae of atrial, ventricular, and sequential atrioventricular pacing in cardiac patientsAmerican Heart Journal, 1966
- Cardiac PacemakingAnnals of Internal Medicine, 1965
- Effect of alterations in ventricular rate on cardiac output in complete heart blockThe American Journal of Cardiology, 1964
- Hemodynamic sequelae of idioventricular pacemaking in complete heart blockThe American Journal of Cardiology, 1963