True Aneurysm Formation in Axillofemoral Bypass with a Reinforced ePTFE Graft
Authors:
- Bilgehan Savas OzBOBilgehan Savas Oz
- Ahmet Turan YilmazAYAhmet Turan Yilmaz
- Celalettin GunayCGCelalettin Gunay
- Nail BulakbaşiNBNail Bulakbaşi
- 1 July 2002
- journal article
- research article
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 36 (4) , 327-329
Abstract
Since improvement in reinforced expanded polytetrafluoroethylene (ePTFE) grafts, true aneurysm and pseudoaneurysm formation have become relatively rare complications after axillofemoral reconstruction. This is a case report of a true aneurysm of an axillofemoral graft. The true aneurysm occurred 29 months after insertion of a reinforced ePTFE graft for aortoiliac occlusive disease. A mid-graft true aneurysm was identified during examinations without any trauma history. Continuous long-term follow-up is recommended for these reinforced ePTFE grafts because of rare aneurysm formation, preferably using duplex ultrasonography.Keywords
This publication has 3 references indexed in Scilit:
- Nonanastomotic pseudoaneurysm of expanded polytetrafluoroethylene axillofemoral bypass graftJournal of Vascular Surgery, 1993
- Late false aneurysm formation along an axillobifemoral graftEuropean Journal of Vascular Surgery, 1991
- Clinical results of axillobifemoral bypass using externally supported polytetrafluoroethyleneJournal of Vascular Surgery, 1990