Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens
Authors:
- Robert Montés-MicóRobert Montés-Micó
- Teresa Ferrer-BlascoTFTeresa Ferrer-Blasco
- Neil W. CharmanNCNeil W. Charman
- Alejandro CerviñoAlejandro Cerviño
- José F. AlfonsoJAJosé F. Alfonso
- Luis Fernández-VegaLFLuis Fernández-Vega
- 1 May 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (5) , 763-768
Abstract
To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations. University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain. Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (< or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective distances. Wavefront aberrations were measured before and after surgery. Aberrations for 2 pupil diameters (3.0 mm and 5.0 mm) were decomposed using Zernike polynomials; total, defocus, astigmatism spherical, and coma aberration terms were studied separately. Postimplantation results were compared with preoperative values. Safety and efficacy indices for distance vision were 1.01 and 0.96, respectively. At near, they improved to 1.07 and 1.06, respectively. Vision at intermediate distances was noticeably poorer. Total, defocus, and spherical aberrations changed after IOL implantation with both pupil diameters (P<.01). Total and defocus aberrations were significantly reduced postoperatively. Spherical aberration coefficients changed to negative and less positive values for a 3.0 mm and a 5.0 mm pupil, respectively. Implantation of the pseudoaccommodating IOL in healthy eyes yielded uncorrected levels of high-contrast, distance, and near acuities comparable to preoperative best corrected values. Higher-order aberration levels appeared to be similar to the preoperative values.Keywords
This publication has 25 references indexed in Scilit:
- Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Prospective visual evaluation of apodized diffractive intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Quality of vision with the Acri.Twin asymmetric diffractive bifocal intraocular lens systemJournal of Cataract & Refractive Surgery, 2007
- ReSTOR intraocular lens implantation in cataract surgery: Quality of visionJournal of Cataract & Refractive Surgery, 2006
- Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Visual Performance of AcrySof ReSTOR Apodized Diffractive IOL: A Prospective Comparative TrialAmerican Journal of Ophthalmology, 2006
- History and development of the apodized diffractive intraocular lensJournal of Cataract & Refractive Surgery, 2006
- European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular LensOphthalmology, 2006
- Postblink changes in total and corneal ocular aberrations*1Ophthalmology, 2004