Development of antithunder composite insulator for distribution line
Authors:
- 7 November 2019
- journal article
- research article
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 15 (1) , 100-107
Abstract
In this article, the antithunder composite insulator combining a surge arrester and insulator is developed. The insulation design and configuration principle of the composite insulator are analyzed through experiments and simulation. The studies of insulation performance have shown that the external breakdown air distance is 60 mm, and the length of the polymeric support insulator is 70 mm. Considering the more serious pollution (0.3 mg/cm2), the creepage distance of the insulation section must be larger than 250 mm. Test data of the antithunder composite insulator meet the standard requirements. The analysis of mechanical performance of the antithunder composite insulator is carried out, which shows that the overall mechanical strength needs to be greater than 2.38 kN. A three‐dimensional (3D) element finite model is built to simulate the behavior of the antithunder composite insulator in the distribution line. The simulation results indicate that the stress on the varistor and the core rod decreases with the increase of the size of the core rod. A core rod of 20 mm or more can meet the operation requirements. The simulation indicates that the stress of the varistor determines the force limit of the antithunder composite insulator. Therefore, attention should be paid to the performance stability of the varistor of the antithunder insulator under force. © 2019 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.Keywords
Funding Information
- State Grid Corporation of China Science and Technology Program (5216A01700UD)
This publication has 13 references indexed in Scilit:
- Study on the flashover performance of an anti‐thunder composite insulator under ice accretion conditions for a 10 kV distribution lineIEEJ Transactions on Electrical and Electronic Engineering, 2018
- Electrical performance of 330-kV composite insulators with different shed configurations under icing conditionsIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Development of Arc-Guided Protection Devices Against Lightning Breakage of Covered Conductors on Distribution LinesIEEE Transactions on Power Delivery, 2009
- Movement Simulation of Three-Phase Short-Circuit Arcs on Distribution Lines Based on the Coupling of Magnetic Field and MotionIEEE Transactions on Plasma Science, 2008
- Influence of Series Gap Structures on Lightning Impulse Characteristics of 110-kV Line Metal–Oxide Surge ArrestersIEEE Transactions on Power Delivery, 2008
- Development of Surge Arresters With Series Gap Against Lightning Breakage of Covered Conductors on Distribution LinesIEEE Transactions on Power Delivery, 2007
- Mechanical Strength and Microstructure of Zinc Oxide Varistor CeramicsJournal of the American Ceramic Society, 2004
- Finite element modelling of the electrical impulse induced fracture of a high voltage varistorJournal of the European Ceramic Society, 2000
- Development of current limiting arcing horn for prevention of lightning faults on distribution linesIEEE Transactions on Power Delivery, 1988
- Prevention of Covered Conductor Burndown on Distribution Circuits-Arcing Protection DevicesIEEE Transactions on Power Apparatus and Systems, 1982