Coherence revival multiplexed, buffered swept source optical coherence tomography: 400 kHz imaging with a 100 kHz source
- 18 June 2014
- journal article
- Published by Optica Publishing Group in Optics Letters
- Vol. 39 (13) , 3740-3743
Abstract
The effective speed of a swept source optical coherence tomography (SSOCT) imaging system was quadrupled using efficient sweep buffering along with coherence revival and spatial multiplexing. A polarizing beam splitter and fold mirror assembly were used to create a dual spot sample arm with a common objective designed for near-diffraction-limited retinal imaging. Using coherence revival, a variable optical delay line allowed for separate locations within a sample to be simultaneously imaged and frequency encoded by carefully controlling the optical path length of each sample path. This method can be used to efficiently quadruple the imaging speed of any SSOCT system employing a low duty-cycle laser that exhibits coherence revival. The system was used to image the retina of healthy human volunteers.Keywords
Funding Information
- Fitzpatrick Foundation (Fitzpatrick Scholar (DN))
- National Eye Institute (NEI) (EY014743, EY019411)
This publication has 12 references indexed in Scilit:
- Efficient sweep buffering in swept source optical coherence tomography using a fast optical switchBiomedical Optics Express, 2012
- Simultaneous swept source optical coherence tomography of the anterior segment and retina using coherence revivalOptics Letters, 2012
- Complex conjugate resolved heterodyne swept source optical coherence tomography using coherence revivalBiomedical Optics Express, 2012
- Ultrahigh speed 1050nm swept source / Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per secondOptics Express, 2010
- Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentationOptics Express, 2010
- Multi-Megahertz OCT: High quality 3D imaging at 20 million A-scans and 45 GVoxels per secondOptics Express, 2010
- High-power wavelength-swept laser in Littman telescope-less polygon filter and dual-amplifier configuration for multichannel optical coherence tomographyOptics Letters, 2009
- Wide-field schematic eye models with gradient-index lensJournal of the Optical Society of America A, 2007
- Signal and Resolution Enhancements in Dual Beam Optical Coherence Tomography of the Human EyeJournal of Biomedical Optics, 1998
- Optical measurement of the axial eye length by laser Doppler interferometry.1991