Durability after aortic valve replacement with the Mitroflow versus the Perimount pericardial bioprosthesis: a single-centre experience in 2393 patients
- 16 March 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (6) , 1705-1710
Abstract
OBJECTIVES This study compares the durability and risk of reoperation in patients undergoing aortic valve replacement (AVR) with either a Mitroflow or a Carpentier-Edwards (CE) pericardial bioprosthesis. Since AVR with bioprosthetic valves has increased progressively in recent years as compared to mechanical valves, especially in patients aged 60–70 years, there has been renewed interest in the long-term durability of current pericardial bioprostheses. METHODS We compared 440 AVR with Mitroflow valves with 1953 AVR with CE pericardial valves implanted from 1999 to 2014 with regard to reoperation, reoperation for structural valve deterioration (SVD) and all-cause mortality. RESULTS Ten-year freedom from explant of any cause was higher for CE Perimount (98 ± 0.7%) than for Mitroflow (95 ± 1.4%, P < 0.01). Reasons for explant for CE Perimount were SVD (n = 2), endocarditis (n = 8) and paraprosthetic leak (n = 10). The reasons for explant for Mitroflow were SVD (n = 11), endocarditis (n = 3) SVD and pericarditis (n = 1) and paraprosthetic leak (n = 2). Ten-year freedom from explant due to SVD was higher for CE Perimount (100%) than for Mitroflow (96%) (P < 0.01). In small aortic annuli (bioprosthesis size 19–21 mm), freedom from SVD at 10 years for CE Perimount and Mitroflow was 100 versus 96%, respectively. By multivariate analysis, it was found that bioprosthesis size was not a risk factor for SVD. The choice of valve type could not be demonstrated to influence long-term survival. CONCLUSIONS The Mitroflow pericardial bioprosthesis provides less than optimal mid- and long-term durability compared with the CE Perimount pericardial valve, especially for small aortic diameter implants (19 and 21 mm). This study hereby confirms the existence of a real risk of valvular deterioration of the Mitroflow valve that might compromise the prognosis of the patients.Keywords
This publication has 19 references indexed in Scilit:
- Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years ExperienceThe Annals of Thoracic Surgery, 2013
- Guidelines on the management of valvular heart disease (version 2012)European Journal of Cardio-Thoracic Surgery, 2012
- 20 years’ durability of Carpentier-Edwards Perimount stented pericardial aortic valve2010
- Mitroflow aortic pericardial bioprosthesis — clinical performance☆☆☆European Journal of Cardio-Thoracic Surgery, 2009
- Aortic valve replacement with the Mitroflow pericardial bioprosthesis: Durability results up to 21 yearsThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Very Long-Term Survival Implications of Heart Valve Replacement With Tissue Versus Mechanical Prostheses in Adults <60 Years of AgeCirculation, 2007
- Mitroflow Synergy Prostheses for Aortic Valve Replacement: 19 Years Experience With 1,516 PatientsThe Annals of Thoracic Surgery, 2005
- Durability of pericardial versus porcine aortic valvesJACC, 2004
- Ten-year echocardiographic and clinical follow-up of aortic Carpentier-Edwards pericardial and supraannular prosthesis: a case-match studyThe Annals of Thoracic Surgery, 2002
- Hemodynamic stability during 17 years of the carpentier-edwards aortic pericardial bioprosthesisThe Annals of Thoracic Surgery, 2002