Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement
Authors:
- 30 October 2009
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 89 (5) , 417-422
Abstract
To evaluate the accuracy of corneal surgically induced astigmatism (SIA) estimation when neglecting the posterior corneal surface measurement. Fifty right eyes undergoing phacoemulsification were measured with a rotating Scheimpflug camera (Pentacam; Oculus Inc., Wetzlar, Germany) both before and after surgery. Clear corneal incisions with one suture were used in the phacoemulsification surgery. The keratometric corneal SIA (KSIA) was derived using the anterior corneal surface measurement and the keratometric index (1.3375) while neglecting the posterior corneal surface measurement. The Pentacam-derived total corneal SIA (PSIA) was derived by vergence tracing and polar value analysis [KP(135) and KP(180)] of the measurements on both corneal surfaces. The mean arithmetic estimation errors of the KSIA for the PSIA were 0.16 ± 0.32 (-0.52 to 1.14) D for the KP(135), and -0.02 ± 0.30 (-0.75 to 1.29) D for the KP(180). There was a significant difference between the KP(135) components of the KSIA and PSIA. Bivariate analysis revealed a statistically significant difference between the combined means of the KSIA and PSIA. Overall, 24% had either a KP(135) component of the KSIA that differed by > 0.50 D from that of the PSIA or a KP(180) component of the KSIA that differed by > 0.50 D from that of the PSIA. The blurring strength caused by neglecting the posterior corneal measurement was > 0.50 D in 24% of eyes. Neglecting the posterior corneal surface measurement may lead to significant deviation in the corneal SIA estimation after phacoemulsification in a proportion of eyes.Keywords
This publication has 30 references indexed in Scilit:
- Correction of astigmatism at the time of cataract surgeryCurrent Opinion in Ophthalmology, 2009
- Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens resultsJournal of Cataract & Refractive Surgery, 2008
- Validity of the keratometric index: Evaluation by the Pentacam rotating Scheimpflug cameraJournal of Cataract & Refractive Surgery, 2008
- Validity of the keratometric index: Large population-based studyJournal of Cataract & Refractive Surgery, 2007
- Comparison of Three Methods of Measuring Corneal Thickness and Anterior Chamber DepthAmerican Journal of Ophthalmology, 2006
- Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetryJournal of Cataract & Refractive Surgery, 2005
- Bivariate analysis of surgically induced regular astigmatism. Mathematical analysis and graphical displayOphthalmic and Physiological Optics, 1999
- Posterior Corneal Surface Toricity and Total Corneal AstigmatismOptometry and Vision Science, 1991
- Measurement of Posterior Corneal Surface ToricityOptometry and Vision Science, 1990
- On the calculation of power from curvature of the cornea.British Journal of Ophthalmology, 1986