This paper presents a full 3D study of a shielded ECT sensor. The spatialresolution and effective sensing field are obtained by means of Finite Element Methodbased simulations and are the compared to a conventional sensor's characteristics. Aneffective improvement was found in the sensitivity in the pipe cross-section, resulting inenhanced quality of the reconstructed image. The sensing field along the axis of the sensoralso presents better behaviour for a shielded sensor.Keywords
This publication has 5 references indexed in Scilit:
- Image reconstruction algorithms for electrical capacitance tomographyMeasurement Science and Technology, 2002
- A highly adaptive electrical impedance sensing system for flow measurementMeasurement Science and Technology, 2002
- Electrode configurations for improved spatial resolution in electrical impedance tomographyMeasurement Science and Technology, 2002
- Three-dimensional analysis of electrical capacitance tomography sensing fieldsMeasurement Science and Technology, 1999