The initial intracranial pressure spike phenomenon
Authors:
- 11 September 2023
- journal article
- research article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 165 (11) , 3239-3242
Abstract
Background Elective use of intraparenchymal intracranial pressure (ICP) monitoring is a valuable resource in the investigation of hydrocephalus and other cerebrospinal fluid disorders. Our preliminary study aims to investigate ICP changes in the immediate period following dural breach, which has not yet been reported on. Method This is a prospective cohort study of patients undergoing elective ICP monitoring, recruited between March and May 2022. ICP readings were obtained at opening and then at 5-min intervals for a 30-min duration. Results Ten patients were recruited, mean age 45 years, with indications of a Chiari malformation (n = 5), idiopathic intracranial hypertension (n = 3) or other ICP-related pathology (n = 2). Patients received intermittent bolus sedation (80%) vs general anaesthesia (20%). Mean opening pressure was 22.9 mmHg [± 6.0], with statistically significant decreases present every 5 min, to a total reduction of 15.2 mmHg at 20 min (p = < 0.0001), whereafter the ICP plateaued with no further statistical change. Discussion Our results highlight an intracranial opening pressure ‘spike’ phenomenon. This spike was 15.2 mmHg higher than the plateau, which is reached at 20 min after insertion. Several possible causes exist which require further research in larger cohorts, including sedation and pain response. Regardless of causation, this study provides key information on the use of ICP monitoring devices, guiding interpretation and when to obtain measurements.Keywords
This publication has 16 references indexed in Scilit:
- Intracranial pressure after the BEST TRIP trialCurrent Opinion in Critical Care, 2014
- Clinical and radiological findings in long-term intracranial pressure monitoringActa Neurochirurgica, 2014
- The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic dischargesBioMedical Engineering OnLine, 2011
- Continuous intracranial pressure monitoring in pseudotumour cerebri: Single centre experienceBritish Journal Of Neurosurgery, 2010
- Diagnostic Intracranial Pressure Monitoring and Surgical Management in Idiopathic Normal Pressure HydrocephalusNeurosurgery, 2010
- MULTICENTER CLINICAL ASSESSMENT OF THE RAUMEDIC NEUROVENT-P INTRACRANIAL PRESSURE SENSORNeurosurgery, 2008
- Inhalational or intravenous anesthetics for craniotomies? Pro inhalationalCurrent Opinion in Anaesthesiology, 2006
- Effect of alfentanil on intracranial pressure during propofol–fentanyl anesthesia for craniotomy. A randomized prospective dose–response studyActa Anaesthesiologica Scandinavica, 2005
- Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by the BrainIT groupActa Neurochirurgica, 2004
- Monitoring and interpretation of intracranial pressureJournal of Neurology, Neurosurgery & Psychiatry, 2004