Oral Versus Nasal High-Flow Bronchodilator Inhalation in Chronic Obstructive Pulmonary DiseaseNotation of prior abstract notification: Parts of the results were presented at ATS congress in 2017 as a thematic poster presentation.
Authors:
- 1 August 2018
- journal article
- research article
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 31 (4) , 248-254
Abstract
Nasal high flow (NHF) alters breathing patterns, stabilizes fraction of inspired oxygen (FiO2) during respiratory distress, helps to keep up hemostasis in the airways, and washes out the upper airways. Particularly the support of inspiratory flow and decrease in functional dead space are interesting mechanisms of action with regard to aerosol delivery. Several laboratory investigations have studied aerosol delivery via the nasal route by using NHF, whereas clinical benefits are poorly evaluated. Thirty patients with stable chronic obstructive pulmonary disease Gold D were recruited. In a randomized order, they inhaled a salbutamol 2.5 mg/ipratropium bromide 500 μg solution oral or NHF adapted on the second study day. A jet nebulizer was used as aerosol delivery device. The chosen flow rate was 35 L/min. Four patients refused to repeat the procedure, for example, for inconvenience or fear of delayed discharge, and were not included in the intention-to-treat analysis. All remaining patients tolerated both inhalation systems well. Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), airway resistance (Rtot), and residual volume (RV) were significantly altered after bronchodilator inhalation with each of the both devices. The two different ways of combined bronchodilator inhalation resulted in very comparable changes in FVC, FEV1, relative 1 second-capacity (FEV1%FVC), Rtot, total lung capacity (TLC), RV, and residual volume expressed as percent of TLC (RV%TLC). However, in between devices, no difference was observed on comparing the postinhalational measurements of FVC, FEV1, Rtot, and RV. We conclude from this proof-of-principle kind of study that inhalation of combined bronchodilators adapted to an NHF device is similarly effective to inhalation with a standard oral aerosol nebulizer. (Clinical Trails NCT02885103).Keywords
This publication has 27 references indexed in Scilit:
- Nasal High-Flow versus Venturi Mask Oxygen Therapy after Extubation. Effects on Oxygenation, Comfort, and Clinical OutcomeAmerican Journal of Respiratory and Critical Care Medicine, 2014
- Nasal versus oral aerosol delivery to the “lungs” in infants and toddlersPediatric Pulmonology, 2014
- Influences of Cannula Size and Flow Rate on Aerosol Drug Delivery Through the Vapotherm Humidified High-Flow Nasal Cannula SystemPediatric Critical Care Medicine, 2013
- Effects of Nasal High Flow on Ventilation in Volunteers, COPD and Idiopathic Pulmonary Fibrosis PatientsRespiration, 2012
- Successful Epoprostenol Withdrawal in Pulmonary Arterial Hypertension: Case Report and Literature ReviewRespiratory Care, 2012
- In vitro comparison of heliox and oxygen in aerosol delivery using pediatric high flow nasal cannulaPediatric Pulmonology, 2011
- Aerosol Delivery through Nasal Cannulas: An In Vitro StudyJournal of Aerosol Medicine and Pulmonary Drug Delivery, 2008
- Outcomes for COPD pharmacological trials: from lung function to biomarkersEuropean Respiratory Journal, 2008
- Performance of six types of oxygen delivery devices at varying respiratory rates*Anaesthesia, 2007
- Comparison of nebulised aerosol deposition in the lungs of healthy adults following oral and nasal inhalation.Thorax, 1993