Application of dual internal standards for precise sizing of polymerase chain reaction products using capillary electrophoresis
Authors:
- 1 January 1995
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 16 (1) , 974-980
Abstract
Capillary electrophoresis (CE) is an analytical technique which provides rapid, high resolution analysis of amplified DNA fragments produced by the polymerase chain reaction (PCR). In this study, two internal standards are used as size markers to bracket und precisely size PCR products. The technique is applied to typing PCR products from the short tandem repeat locus HUMTH01. HUMTH01 consists of five to seven major alleles in the size range of 179–203 bp, with each allele four bp apart. Using this genetic marker, a population containing 97 individuals was examined with both polyacrylamide gel electrophoresis and CE. Identical genotypes were obtained with both techniques demonstrating the reliability of CE in DNA typing applications. The DNA analysis took place in sets of 10 with a calibration of the CE being performed between each set of samples. For the 97 samples examined, the pooled standard deviation was 0.3 bp. The observed genotype frequencies determined from the sample set did not deviate significantly from Hardy‐Weinberg expectations. From these CE results, we conclude that HUMTH01 PCR products can be accurately and precisely sized by capillary electrophoresis using the method described.Keywords
This publication has 29 references indexed in Scilit:
- Advanced methods in PCR product detection.Genome Research, 1994
- Basic methods for the detection of PCR products.Genome Research, 1994
- Fluorescent‐based typing of the two short tandem repeat loci HUMTH01 and HUMACTBP2: Reproducibility of size measurements and genetic variation in the swedish populationElectrophoresis, 1994
- Variation in Short Tandem Repeat sequences ?a survey of twelve microsatellite loci for use as forensic identification markersInternational journal of legal medicine, 1994
- Forensic validation of the STR systems SE 33 and TC 11International journal of legal medicine, 1993
- Automated DNA profiling employing multiplex amplification of short tandem repeat loci.Genome Research, 1993
- High Resolution Capillary Electrophoresis of Forensic DNA Using a Non-Gel Sieving BufferJournal of Liquid Chromatography, 1993
- Evaluation of on‐column labeling with intercalating dyes for fluorescence detection of DNA fragments separated by capillary electrophoresisJournal of Microcolumn Separations, 1993
- Capillary electrophoresis of DNA restriction fragments with solutions of entangled polymersElectrophoresis, 1993
- Capillary electrophoresis of DNA fragments in entangled polymer solutions: A study of separation variablesJournal of Microcolumn Separations, 1992