Head motion correction based on filtered backprojection for x‐ray CT imaging
Authors:
- 22 December 2017
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 45 (2) , 589-604
Abstract
Purpose: For head x‐ray CT imaging, the head needs to remain motionless during the scan. In clinical practice, however, head motion is sometimes unavoidable depending on the patient. The motion can occur abruptly during the scan and can be unpredictable. It thereby causes motion artifacts such as tissue blurring or doubled edges around the skull area. To mitigate this problem, we propose a 3D head motion estimation (ME) and compensation algorithm based on filtered backprojection.Methods: If a patient moves his or her head during the scan, a motion‐corrupted sinogram is obtained. Modeling the head motion as a 3D rigid transformation, we develop a motion‐compensated (MC) reconstruction algorithm based on the FDK algorithm. To determine the head motion of a rigid transformation, we propose two optimization‐based ME schemes depending on the degree of head motion, both of which are performed by updating motion parameters and the corresponding MC reconstructed image alternatively until the proposed cost function is minimized for the MC reconstructed image. In particular, to improve the robustness in the case of large motion, we propose attaching a fiducial marker to the head so that more reliable motion parameters can be initialized by determining the marker position, before the optimization. To evaluate the proposed algorithm, a numerical phantom with realistic, continuous, and smoothly varying motion, and a moving physical phantom are used with a gantry rotation time of 1 s.Results: In the simulation using a numerical phantom and in the experiment using a physical phantom, the proposed algorithm provides well‐restored 3D motion‐compensated images in both cases of small and large motion. In particular, in the case of large motion of the physical phantom, using a fiducial marker, we obtain remarkable improvement of image quality in cerebral arteries and a lesion as well as the skull. Quantitative evaluations using the image sharpness and root‐mean‐square error also show noticeable improvement of image quality in both simulations and experiments.Conclusions: We propose a framework for head motion correction in an axial CT scan, which consists of motion estimation and compensation steps. Two image‐based ME algorithms for rigid motion tracking are developed according to the degree of head motion. The estimated motion information is then used for MC image reconstruction. Both motion estimation and compensation algorithms are based on computationally efficient filtered backprojection. Excellent performance of the proposed framework is illustrated by means of simulations using a numerical phantom and experiments using a physical phantom.Keywords
Funding Information
- Samsung Electronics
This publication has 40 references indexed in Scilit:
- Fiducial marker‐based correction for involuntary motion in weight‐bearing C‐arm CT scanning of knees. Part I. Numerical model‐based optimizationMedical Physics, 2013
- Image features for misalignment correction in medical flat‐detector CTMedical Physics, 2012
- An Efficient Estimation Method for Reducing the Axial Intensity Drop in Circular Cone‐Beam CTInternational Journal of Biomedical Imaging, 2008
- Quantification and Clinical Relevance of Head Motion During Computed TomographyInvestigative Radiology, 2003
- Temporal resolution and the evaluation of candidate algorithms for four‐dimensional CTMedical Physics, 2003
- Retrospective correction of MR intensity inhomogeneity by information minimizationIEEE Transactions on Medical Imaging, 2001
- A general cone-beam reconstruction algorithmIEEE Transactions on Medical Imaging, 1993
- A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomographyIEEE Transactions on Medical Imaging, 1992
- Cone beam tomography with circular, elliptical and spiral orbitsPhysics in Medicine & Biology, 1992
- Optimal short scan convolution reconstruction for fan beam CTMedical Physics, 1982