Abstract
This study investigates how Kolmogorov–Arnold Networks (KANs) behave when combined with semi-supervised learning for single-lead ECG analysis. Three architectures are compared: a standard CNN-BiLSTM-Attention model (accurate but uninterpretable), a minimal KAN with a simple CNN front-end (ablation), and the proposed SE-MSC-KAN-CNN. The proposed model uses multi-scale depthwise convolutions, Squeeze-and-Excitation attention, BiLSTM, and a B-spline KAN head. Interpretability is evaluated in three ways: visualising learned B-spline functions, applying Grad-CAM to highlight important signal regions, and measuring how the splines change when fewer labels are used (spline drift). On the PhysioNet 2017 dataset (8528 recordings, four classes), the proposed model reaches 85.2% supervised accuracy ( F 1 = 0.851), outperforming the CNN baseline (83.1%) and matching much larger black-box models. With only 90% of the labels, it still achieves 85.1%. After training, we applied post-training TFLite INT8 conversion. Only the CNN-front-end KAN converted (measured size 422 KB). The proposed SE-MSC-KAN-CNN did not convert, because Bidirectional LSTM and custom attention lack TFLite kernels; its float32 footprint is about 9.8 MB (theoretical INT8 size about 806 KB). Classification metrics in this paper are float32; INT8 test accuracy was not measured. The spline drift metric summarises how KAN coefficients change under semi-supervised training; use as an on-device out-of-distribution detector is proposed but not validated here. These results show that competitive accuracy and inspectable KAN maps can be obtained in one hybrid architecture. Wearable deployment of the proposed SE-MSC-KAN-CNN is not yet achieved: TFLite INT8 conversion failed, and the present graph still requires float32 inference.Keywords
Funding Information
- RIIM LPDP Kompetisi (RIIM 2024-02 G6)
This publication has 39 references indexed in Scilit:
- Interpretable deep learning framework for multi-label ECG classification: Enhancing cardiac diagnostics through feature attention and explainabilityBiomedical Signal Processing and Control, 2025
- SmartMatch: A semi-supervised framework for obstructive sleep apnea classification using single-lead electrocardiogram signals with limited annotationsEngineering Applications of Artificial Intelligence, 2025
- A lightweight intrusion detection approach for CAN bus using depthwise separable convolutional Kolmogorov Arnold networkScientific Reports, 2025
- Automated ECG Analysis with Dual-Channel SqueezeNet Using Hilbert Huang Transform, Fuzzy Entropy, and Hurst ExponentCircuits, Systems, and Signal Processing, 2025
- FedECG: A federated semi-supervised learning framework for electrocardiogram abnormalities predictionJournal of King Saud University Computer and Information Sciences, 2023
- An accurate and efficient method to train classifiers for atrial fibrillation detection in ECGs: Learning by asking better questionsComputers in Biology and Medicine, 2022
- Smartwatch biomarkers and the path to clinical useMed, 2021
- A review on deep learning methods for ECG arrhythmia classificationExpert Systems with Applications: X, 2020
- Opportunities and challenges of deep learning methods for electrocardiogram data: A systematic reviewComputers in Biology and Medicine, 2020
- Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural networkNature Medicine, 2019