Determining the local origin of hydroxyl radical generation during phacoemulsification
Authors:
- Scott TerrySTScott Terry
- Thomas HebdonTHThomas Hebdon
- Broc GundersonBGBroc Gunderson
- Michael TerryMTMichael Terry
- Ramon DimalantaRDRamon Dimalanta
- 1 June 2011
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (6) , 1154-1159
Abstract
To determine the local origin of hydroxyl radicals during phacoemulsification using an ultrasonic phacoemulsification device that includes longitudinal and torsional modalities. Chemistry and Biochemistry Department, Utah State University, Logan, Utah, USA. Experimental study. Experiments were conducted using the Infiniti Vision System and Ozil handpiece. Hydroxyl radical concentrations during longitudinal and torsional phacoemulsification were quantitated as malondialdehyde (MDA) determined spectrophotometrically using the deoxyribose assay. The difference between the total concentration found in the aspirated solution at steady-state concentrations and the pre-aspirate levels deductively determined the concentration of MDA formed along the interior of the sonicating tip. The time to reach 50% of steady state as a function of reaction vessel volume was determined. The mean maximum for torsional ultrasound at 100% amplitude was 7.70 nM ± 0.38 (SD), 91.1% of which was generated outside the tip. During longitudinal ultrasound at 100% power, MDA concentration in the aspirated solution was 29.5 ± 0.3 nM, 71.6% of which was generated outside the tip. The time (seconds) to reach 50% of maximum for longitudinal ultrasound using 5 mL, 10 mL, and 20 mL reaction vessels was 12.6 ± 1.5, 21.0 ± 1.5, and 25.3 ± 3.4, respectively. Although a significantly greater proportion of the hydroxyl radicals generated during ultrasound modality were formed outside the phaco tip (91.1% torsional; 71.6% longitudinal), torsional ultrasound generated only about one-fourth the amount of MDA as longitudinal ultrasound in total and about one-third that generated outside the tip (7.02 nM versus 21.1 nM). No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.Keywords
This publication has 15 references indexed in Scilit:
- Emulsification action of longitudinal and torsional ultrasound tips and the effect on treatment of the nucleus during phacoemulsificationJournal of Cataract & Refractive Surgery, 2010
- Quantification of hydroxyl radical produced during phacoemulsificationJournal of Cataract & Refractive Surgery, 2009
- Heat production: Longitudinal versus torsional phacoemulsificationJournal of Cataract & Refractive Surgery, 2009
- Phacoemulsification-induced injury in corneal endothelial cells mediated by apoptosis: In vitro modelJournal of Cataract & Refractive Surgery, 2008
- Torsional mode versus conventional ultrasound mode phacoemulsificationJournal of Cataract & Refractive Surgery, 2007
- Innovations in phacoemulsification technologyCurrent Opinion in Ophthalmology, 2007
- Alteration of free radical development by ophthalmic viscosurgical devices in phacoemulsificationJournal of Cataract & Refractive Surgery, 2006
- The physics of phaco: A reviewJournal of Cataract & Refractive Surgery, 2005
- Identification of free radicals produced during phacoemulsificationJournal of Cataract & Refractive Surgery, 2001
- Free radical formation induced by ultrasound and its biological implicationsFree Radical Biology and Medicine, 1992