Quantitation of estradiol by competitive light‐initiated chemiluminescent assay using estriol as competitive antigen
Authors:
Open Access
- 24 August 2019
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 34 (1) , e23014
Abstract
Background: Light‐initiated chemiluminescent assays (LICA) are homogeneous assays that are sensitive, specific, and free of separation and washing steps and have high throughput and high precision. Methods: In this research, we developed a competitive method by LICA to achieve accurate quantification of estradiol (E2) in human serum. E2 competed with estriol (E3) for binding to anti‐human E2 antibodies. E3 was linked to biotin via bovine serum albumin as a linker. As this assay used competition between the labeled tracer and the analyte, an increase in E2 concentration will cause a signal decrease. Results: The expected detection range of E2 was 20‐5000 pg/mL. The analytical and functional sensitivities were 7.16 and 13.7 pg/mL, respectively. The intra‐ and inter‐assay coefficients of variation were both below 15%, and the recovery rate ranged from 97.5% to 106.8%. The interference rates ranged from −3.6% to 5.4% and met detection requirements for E2 in hyperbilirubinemia, hemolysis, and lipemia in clinical samples. In addition, the cross‐reactivity rates between E2 and structural analogs and some reproductive hormones varied from 1.9% to 10.6% which showed that LICA is highly specific for E2. Moreover, our results showed high accordance with the IMMULITE 2000 ( y = 0.6695 x + 47.92, r 2 = .843) and VIDAS systems ( y = 1.099 x − 821.5, r 2 = .9392). Conclusion: Our data show that the LICA, which is easy to automate, is a promising technique for quantification of E2 in human serum and could be used for clinical detection.Keywords
Funding Information
- National Natural Science Foundation of China (81772259)
This publication has 40 references indexed in Scilit:
- Competitive light-initiated chemiluminescent assay: using 5-α-dihydrotestosterone-BSA as competitive antigen for quantitation of total testosterone in human seraAnalytical and Bioanalytical Chemistry, 2018
- Data to support a simultaneous testosterone and estradiol assay in serum by LC-MS/MSData in Brief, 2018
- Development of a light-initiated chemiluminescent assay for the quantitation of sIgE against egg white allergens based on component-resolved diagnosisAnalytical and Bioanalytical Chemistry, 2017
- Donor/acceptor nanoparticle pair-based singlet oxygen channeling homogenous chemiluminescence immunoassay for quantitative determination of bisphenol AAnalytical and Bioanalytical Chemistry, 2016
- Simultaneous Quantitation of Estradiol and Estrone in Serum Using Liquid Chromatography Mass Spectrometry2016
- Rational design of a low-affinity peptide for the detection of cystatin C in a fast homogeneous immunoassayAmino Acids, 2015
- Bringing GC–MS profiling of steroids into clinical applicationsMass Spectrometry Reviews, 2014
- Analytical strategies based on chromatography–mass spectrometry for the determination of estrogen-mimicking compounds in foodJournal of Chromatography A, 2013
- Comparative endocrinological and clinical effects of percutaneous estradiol and oral conjugated estrogens as replacement therapy in menopausal womenMaturitas, 1991